beautypg.com

Performance data sheet – Culligan Aqua-Cleer User Manual

Page 17

background image

15

IMPORTANT NOTICE: Read this Performance Data Sheet and compare the capabilities of the unit with your actual
water treatment needs. Culligan recommends that you have your water supply tested to determine these needs before purchasing
a water treatment unit.

Culligan knows the more informed you are about your water treatment systems, the more confident you
will be about its performance. It’s because of this and more than sixty years of commitment to customer
satisfaction that Culligan is providing this Performance Data Sheet to its customers.

MANUFACTURER:

Culligan International Company,
One Culligan Parkway, Northbrook, IL 60062-6209 USA
(847) 205-6000

PRODUCT: Culligan

®

Aqua-Cleer

®

Good Water Machine

Reverse Osmosis Drinking Water System

MODELS: H-30 SR, H-30 PRV-C

USE GUIDELINES
• Working Pressure: 40-120 psig (280-827 kPa)
• Do not allow exposure to temperatures below 33°F (1°C)
• Maximum operating temperature: 100°F (38°C)
• This system must be installed according to local plumbing codes on the cold water line.
• This sytem requires regular replacement of all filters to maintain proper operation. Depending on

usage and influent water quality, the carbon and particulate filters should be changed at least annually
and the reverse osmosis membrane should be replaced every 3-5 years. Varifying chlorine, sediment or
TDS levels may effect replacement frequency.

• Particulate Prefilter Element ................................ 00-4015-38
• Activated Carbon Prefilter Element ...................... 01-0008-27 or 01-0125-80
• Activated Carbon Postfilter Element ................... 01-0000-79
• Reverse Osmosis Module ..................................... 01-0074-02
• If water production decreases or a noticeable taste change occurs, contact your local Culligan Dealer.

A Culligan professional can determine if your drinking water system requires servicing. Optional water
quality monitors are also available to monitor the performance of the reverse osmosis membrane.

CAUTION:

Do not use with water that is microbiologically unsafe or of unknown quality

without adequate disinfection before or after the system. Systems certified for cyst reduction
may be used on disinfected water that may contain filterable cysts. EPA Est 2938-IL-01.

• The Good Water Sentry™ Water Quality Monitor is another way to keep track of your systems

performance. This optional accessory checks your drinking water each time you use the special faucet,
and signals when the membrane filter may need to be replaced.

SUGGESTED INSTALLATION EQUIPMENT
Sink Cutting Tools

Tools

Porcelain Cutter Kit, 1-1/4 inch diameter, PN 00-5916-25 Screwdriver, blade and Phillips (#1)
Greenlee Hole Punch, 1-1/4 inch diameter

1/8 inch diameter pilot drill for #10 screws

Plumbers Putty

Center Punch

Heavy Duty Drill with speed control to 400 rpm

Razor Blade Knife
Faucet Installation Tool, PN 00-4033-75
Aqua-Cleer

®

H Series or “System” series filter

housing

Performance Data Sheet