Installation warnings, Technical specifications – Windy Nation Windtura 750 (No Slip Ring version) User Manual
Page 7

7
Installation Warnings
Do not assemble or install the Windtura 750 until you have read the entirety of this owner’s
manual!
1. It is necessary to follow the installation instructions and safety precautions included in this
owner’s
manual.
Failure
to
do
so
can
result
in
serious
accidents
including
but
not
limited
to
property
damage,
serious
injury,
and
death.
Additionally,
keep
this
owner’s
manual
after
you
install
your
Windtura
750
Wind
Turbine
as
it
includes
maintenance
information.
2. Before assembling the Windtura 750 inspect all parts for any defects. If you have any questions
or
concerns,
contact
WindyNation
Inc.
or
your
local
distributor
before
proceeding
with
installing
your
Windtura
750.
3. Never
install
a
wind
turbine
on
a
windy
day.
4. Use
proper
electrical
wiring
and
grounding
techniques
which
are
in
compliance
with
your
country’s electrical codes.
5. Tower design and construction should be approved by a professional engineer and also follow
all local and national laws in your respective area.
6. Do not install the Windtura 750 in any location where anyone or anything can come in contact
with
it.
The
Windtura
750
has
moving
parts,
including
high
rpm
blades,
which
can
cause
serious
injury
or
death.
Use
common
sense
when
choosing
a
location
to
mount
the
Windtura
750.
Technical Specifications:
Model
Windtura 750
Rotor Diameter
79 in (200.7 cm)
Net Weight
56 lbs (23.6 kg)
Survival Wind Speed
105 mph (47 m/s or 169 kph)
Initial Power Generator Wind Speed
6-‐8 mph (2.7-‐3.6 m/s)
Rated Power
800 Watts at 29 mph wind speed
Battery Bank Specifications
Suitable for 12 and 24 volt battery banks
Recommended Fuse for 12 volt system
Recommended Fuse 24 volt system
60 amp slow blow
60 amp slow blow