Adjusting the C-Series Voltage Settings

975-0004-01-02 Rev D

27

Figure 2-14 Voltage Settings with R46 Resistor Clipped

CAUTION: Damage to Batteries

It is not recommended to allow an equalize charge to occur if the
R46 Resistor is clipped. Higher charging voltages may damage the
batteries. Make sure the EQ/LVR jumper is on the MANUAL
Setting.

12-Volt System Settings

24-Volt System Settings

17.0

15.0

16.0

BULK (CHG)

15.2

15.4

15.6

15.8

16.2

16.4

16.6 16.8

FLOAT (CHG)

16.5

14.5

15.5

14.7

14.9

15.1

15.3

15.7

15.9

16.1

16.3

48-Volt System Settings (C40 only)

34.0

30.0

32.0

BULK (CHG)

30.4

30.8

31.2

31.6

32.4

32.8

33.2 33.6

FLOAT (CHG)

33.0

29.0

31.0

29.4

29.8

30.2

30.6

31.4

31.8

32.2 32.6

68.0

60.0

64.0

BULK (CHG)

60.8

61.6

62.4

63.2

64.8

65.6

66.4 67.2

FLOAT (CHG)

66.0

58.0

62.0

58.8

59.6

60.4

61.2

62.8

63.6

64.4 65.2