Operating Modes

975-0004-01-02 Rev D

5

Bulk Stage

During this stage, the batteries are charged at the bulk voltage
setting and maximum current output of the DC source. When
the battery voltage reaches the bulk voltage setting, the
controller activates the next stage (absorption).

Absorption Stage

During this stage, the voltage of the battery is held at the bulk
voltage setting until an internal timer has accumulated one
hour. Current gradually declines as the battery capacity is
reached.

Float Stage

During this stage, the voltage of the battery is held at the float
voltage setting. Full current can be provided to the loads
connected to the battery during the float stage from the PV
array. When battery voltage drops below the float setting for
a cumulative period of one hour, a new bulk cycle will be
triggered.

Figure 1-2 3-stage Battery Charging Process

Bulk Stage

Floa t Stage

DC Voltage

DC Current

Constant Current

Reducing Current

Reduced Current

B ulk Vol ts Setti ng

Float V olts Setti ng

Time

Max Amps

Absorpti on Time

Charging

Started

Increasing Vol tage

Constant Vol tage

Reduced Vol tage

0 amps

0 vol ts

Absorption Stage