Installing The Furnace
(cont'd)
19
LOW VOLTAGE ELECTRICAL CONNECTIONS
The outdoor temperature sensor, room thermostat, and peak control signal are low voltage wire connections to
the furnace. All low voltage wiring must be segregated from line voltage circuits in the furnace.
Low Voltage Wiring Diagram
9
NOTES:
1.
Low voltage auxiliary control contacts.
a. Y to Y2 contacts open when load control device closes.
b. Y to Y3 contacts close when load control device closes.
2.
Auxiliary contacts close during offpeak heat calls.
3.
N.O. used for open onpeak load control device (switch closes to charge).
N.C. used for closed onpeak load control device (switch opens to charge).
FIGURE 12