Installing the SmartSwitch 9000 Module

2-4

An eight-position DIP switch is located on the module card as shown in
Figure 2-1. The function of the switches are listed in Table 2-1.

See the

Cautions

at the end of this table.

Table 2-1. Function of DIP Switch

Switch

Function

Description

8

Clear

Password

1

When toggled, this switch clears user-entered
passwords stored in NVRAM, and restores the
default passwords. Once reset you can use the
defaults or enter new passwords.

7

Clear

NVRAM

2

The module uses NVRAM to store user-
entered parameters such as IP addresses,
device name, etc. To reset these parameters to
the factory defaults, toggle this switch. Once
reset, you can use the defaults or enter new
parameters, which are stored in NVRAM
when the module is powered down, and
remain there until the switch is toggled again.

6

Force BootP

Download

Toggling this switch after pulling the board
out of the SmartSwitch 9000, clears download
information from NVRAM and forces image
files to be downloaded from the station
connected to the EPIM on the Environmental
Module configured to act as that modules’
B

oot

P server. (See section titled

Using DIP

Switch 6

on page 2-5.)

5

Reserved

For Factory Use Only

4

Reserved

For Factory Use Only

3

Reserved

For Factory Use Only

2

Reserved

For Factory Use Only

1

Reserved

For Factory Use Only