beautypg.com

Installation, Continued – Desa Tech 107434-01C.pdf User Manual

Page 12

background image

107434-01C

For more information, visit www.desatech.com

For more information, visit www.desatech.com

12

INSTALLATION

Continued

Figure 18 - Attaching Wire Harness to Thermostatic Switch and
Cover Assembly

Thermostatic Switch
Mounted to Cover

Wire Harness

Lower Hole

Figure 17 - Removing Cover Plate

Cover
Plate

Firebox Back
Panel

Screws

5.

Disconnect power cord wires from blower motor (if connected)
(see Figure 13, page 10).

6.

Disconnect green ground wire from blower housing (if con-
nected) by removing screw holding wire terminal (see Figure
13, page 10).

7.

Remove the two blower mounting brackets from the rear panel
by removing two screws each (see Figure 14, page 10).

8.

Attach the two mounting brackets to blower housing using four
screws provided in blower kit (2 for each bracket) (see Figure
14, page 10). Tighten screws securely. Place blower assembly
temporarily on top of firebox.

9.

If screen is installed, carefully lift slightly and pull forward
to remove.

10. If logs are installed, carefully remove and set aside.

11. Remove three screws and cover plate from center of firebox back

panel. Keep screws but discard cover plate (see Figure 17).

12. Locate thermostatic switch/cover plate assembly and wire har-

ness supplied with blower. Attach wire harness terminals to
terminals on thermostatic switch. Push firmly. Make sure the
bottom hole of cover is on the opposite side from the wire
harness (see Figure 18).

13. Feed terminal ends of wire harness into the hole in firebox

back panel from front of firebox. Pull the ends of the harness
to the top of firebox near blower (see Figure 19).

14. Align holes in the switch/cover assembly with holes in firebox

back panel. Using 3 screws from step 11, attach assembly to
firebox back panel. Tighten screws firmly (see Figure 19).

15. Working from the rear of the stove, place entire power cord,

including speed control housing, in lower control compartment
(see Figure 20).

16. Route ends of 3-wire power cord up from the lower control com-

partment through the plastic bushing, then up to the upper cavity
of stove (see Figure 20).

17. Connect white wire from speed control to either terminal on

blower motor (see Figure 20). Push firmly.

Figure 19 - Assembling Thermostatic Switch and Cover to
Firebox Back Panel

Thermostatic
Switch
Mounted to
Cover

Wire
Harness

Hole in Firebox
Back Panel

Screws

Wire Harness

Power Cord

Speed Control
Housing

Control
Knob

Wiring Diagram Decal

Blower

Red Switch
Wire

Green Ground Wire

Ground
Wire
Screw

White Speed
Control Wire

Black Speed
Control Wire

Blue
Switch
Wire

Figure 20 - Connecting Switch, Blower, and Speed Control
Wires

Red

Variable

Fan Switch

Fan Switch

(N.O.)

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

Black

Blue

120 Vac. 60 Hz. 90 Amps

DESA International, Bowling Green, KY

WARNING: Never attempt to service heater while it

is plugged in, operating, or hot. Burns and electrical
shock could result. Only a qualified service person
should service or repair heater.

If any of the original wire as supplied with the appliance must be
replaced, it must be replaced with 105

°

C wire or it’s equivalent.

WARNING: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause im-
proper and dangerous operation. Verify proper operation
after servicing.

INSTALLATION

Installing Optional Blower Accessory GA3650TA (Cont.)