Appendix d: ems-d120 specifications, Appendix d: ems-d120 specifications -4 – Dynon Avionics EMS-D120 Installation Guide User Manual
Page 70
Appendix
7-4
EMS-D120
Installation
Guide
Appendix D: EMS-D120 Specifications
Mechanical
6.95” wide x 4.90” tall x 4.51” deep (177 x 125 x 115 mm)
Operating
Temperature
-22° to 122° F (-30° to 50° C)
Power
Voltage:
10 - 30 Vdc
Power:
12 watts typical; 14 watts maximum
Connections
Wiring:
DB25 female & DB37 male connectors
Screen
Type:
AMLCD, TFT (Thin Film Transistor)
Backlight:
400 nits (or 800 nits, for super-bright option)
Size:
7.0” diagonal (178 mm)
Resolution:
854 x 480 color pixels
Sensor Inputs
6 - EGT (Type K Thermocouple)
6 - CHT (Type J Thermocouple)
2 - Fuel Level (Resistive or Capacitance with 5 volt output)
2 - RPM (P-lead or pickup)
2 - Contacts
1 - Manifold Pressure (voltage)
1 - Oil Temperature (Resistive)
1 - Oil Pressure (Resistive)
1 - Fuel Pressure (Resistive)
1 - Fuel Flow (Frequency)
1 - Current (Shunt)
1 - Voltage (from supply power)
1 - Turbine Inlet Temperature (Type K Thermocouple)
3 - General Purpose (Either resistive or voltage for OAT, Fuel
Tanks 3&4, Coolant Temp, Coolant Press, Carburetor
Temp)
Inputs/Outputs
1 - Alarm Light Contact
1 - Audio Alarm
1 - RS-232 bidirectional PC communication
1 - RS-232 data input (GPS, SL30, etc.)
1 - Dynon Smart Avionics Bus (DSAB) differential