Problem
Solution
After performing a magnetic
calibration the EFIS-D100‘s
heading is wrong by a constant
amount.
Orient your plane in a known direction, preferably on a
compass rose at the airport. Navigate to the Heading
Adjustment menu by pressing SETUP > MORE > MORE >
MAGADJ. Increment or decrement the value of the heading
until the EFIS-D100 heading corresponds to the direction in
which your plane is pointed.
When the barometer on the unit
is set correctly, the displayed
altitude is wrong by a constant
amount at all altitudes.
Set the barometer to the correct value for your current
location. Note the difference between the displayed altitude
and the actual altitude for your location. Navigate to the
Altitude Adjustment menu by pressing SETUP > MORE >
ALTADJ. Increment or decrement the value of the altitude
until the EFIS-D100 altitude corresponds to that of the
current location of your plane. If you need to adjust by more
than 200 ft, or find that you need to adjust frequently (after
setting your baro), please call Dynon Technical Support for
assistance.
Airspeed is inaccurate by
between 1 and 10 knots (or
equivalent, in other units) at
takeoff speed.
You may recalibrate your EFIS-D100‘s zero pressure value.
With your plane in as windless an environment as possible
(e.g., a hangar), cover both the pitot and static ports with a
sock or cloth to minimize airflow without putting pressure
on the ports. Next, on the EFIS-D100, enter the EFIS main
menu, press MORE > SETUP > MORE > MORE > MORE
> SPDCAL. When you are confident that there is no
pressure on the pitot and static ports, press either button
corresponding to SET ZERO PRESSURE. Press YES to
confirm you have zero pressure on the pitot and static ports.
You will see a message indicating that the unit is calibrating.
This should only take a few seconds. On your next flight,
verify that the airspeed is what you expect.
To reset the airspeed calibration to factory defaults, enter the
SPDCAL menu, and press RESET DFLTS.
EFIS-D100 displays continuous
or blinking blue screen
Ensure that your power supply is capable of supplying at
least 2 amps and that it is at least 10 volts.
If, after verifying that you have met these two conditions the
unit does not operate normally, it is necessary to contact
Dynon Avionics.
EFIS-D100 screen stays black
when power is applied
Verify Master Power is connected.
Verify Master Power is above 10 volts.
EFIS-D100 indicates over
temperature condition
Provide additional cooling to instrument
EFIS-D100 indicates incorrect
heading
(Re)calibrate the magnetic heading using the procedure
described above.