Quick Balance User Instructions

Units

Press this softkey to set the following:

l

Unit of measure on power up. Choices are Last*, C2, C1, N, kgf, and
lbf. Use the Sel keys to display your choice and press Enter to
accept it. C2 and C1 are custom units. If you choose to have custom
units, you are prompted to enter the number of pounds in each
custom unit. The Quick Balance will then automatically calculate
correct display for the applied force.

l

Enable lbf - Enable or disable the pound-force unit of measure.

l

Enable kgf - Enable or disable the kilogram-force unit of measure.

l

Enable N - Enable or disable the N unit of measure.

l

Enable CUST1 - Enable or disable the Cust1 unit of measure.

l

Enable CUST2 - Enable or disable the Cust2 unit of measure.

l

Enable C - Enable or disable Centigrade temperature.

l

Enable F - Enable or disable Fahrenheit temperature.

Power

Press this softkey to enable or disable the auto-shutdown. If you enable
this function you are prompted to set a period of time in minutes. Next,
press the Enter softkey to accept this value. You are then asked to set the
shutdown type; Fixed, No Load, or No Change. These are described
below;

Fixed -

The unit will shutdown after the set number of minutes no
matter what happens.

No Load -

The unit will shutdown after the set number of minutes only
if there is no load on the unit. This prevents shutdown in the
middle of line tensioning.

No Change - The unit will shutdown if there has been no keypad activity

or change in tension after the set number of minutes.

ChPwd

Press this key and you are prompted to enter a new password to access
the configuration menus. Use the softkeys to scroll in a new password and
press the Enter softkey to accept it.

Reset

Press this key and you are asked if you wish to reset the system. Press the
Yes softkey only if you want to reset the unit to factory default
configuration. Press the No softkey to abort this and return to the previous
screen.

Custom units of measure are handy when working with multi-part lines.

Default password is 0. If a new password is lost or forgotten, contact your Dillon
distributor.