Canoga Perkins Corp. EdgeAccess Ethernet Media Converter 03-Oct-2005
Model L351-1075 V03.40 F37 Standalone 11:00:54
----------------------------------FUNCTIONAL CONFIGURATION----------------------
Local
Remote
Chassis/Slot
Standalone
Offline
User Port Speed/Duplex
Link Down
Switch Settings:
User Port Speed
10M
User Port Autonegotiation
Enabled
User Port Duplex
Half
Side Band Mgmt
Enabled
LLF Extension to User
Disabled
LLF User to Extension
Disabled
RMTF
Enabled
1) Configuration Option Control
Software
2) User Port Speed/Duplex
10M/Half
3) RMTF
Disabled
4) Link Loss Fwd
Disabled
Hit SPACE: toggle selection. ENTER: accept. ESC: cancel.
------------------------------------Messages------------------------------------
Alarm Outputs: None
Figure 11. Functional Configuration screen
Step 7: Cable Connection
Once the changes are made to the modules, the UTP (Unshielded Twisted Pair) or fiber optic
cables can be installed. Remember that the USR port is the port connected to your local/client
device and the EXT port is the port facing the network/trunk. Connect the fiber to the EXT port.
Figure 12. Fiber optic and UTP cable connection
Step 8: IP Address/Subnet Mask/Default Gateway Set-up
To configure the IP address, select “5,” press enter, and type the IP address you wish to assign to
the unit. Press enter to accept the changes. The Subnet Mask and Default Gateway must be
entered at this point as well, and note that the Subnet Mask and Default Gateway must be in the
same class as the IP address, i.e. Class A, Class B or Class C.