beautypg.com

CANOGA PERKINS L351 ESU User Manual

Page 7

background image

Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008

Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com

P/N 6942580 Rev A

Page 7 of 8

Canoga Perkins Corp. EdgeAccess Ethernet Media Converter 03-Oct-2005
Model L351-1075 V03.40 F37 Standalone 11:00:54
----------------------------------FUNCTIONAL CONFIGURATION----------------------

Local

Remote

Chassis/Slot

Standalone

Offline

User Port Speed/Duplex

Link Down

Switch Settings:
User Port Speed

10M

User Port Autonegotiation

Enabled

User Port Duplex

Half

Side Band Mgmt

Enabled

LLF Extension to User

Disabled

LLF User to Extension

Disabled

RMTF

Enabled


1) Configuration Option Control

Software

2) User Port Speed/Duplex

10M/Half

3) RMTF

Disabled

4) Link Loss Fwd

Disabled



Hit SPACE: toggle selection. ENTER: accept. ESC: cancel.
------------------------------------Messages------------------------------------
Alarm Outputs: None

Figure 11. Functional Configuration screen

Step 7: Cable Connection

Once the changes are made to the modules, the UTP (Unshielded Twisted Pair) or fiber optic
cables can be installed. Remember that the USR port is the port connected to your local/client
device and the EXT port is the port facing the network/trunk. Connect the fiber to the EXT port.

Figure 12. Fiber optic and UTP cable connection

Step 8: IP Address/Subnet Mask/Default Gateway Set-up

To configure the IP address, select “5,” press enter, and type the IP address you wish to assign to
the unit. Press enter to accept the changes. The Subnet Mask and Default Gateway must be
entered at this point as well, and note that the Subnet Mask and Default Gateway must be in the
same class as the IP address, i.e. Class A, Class B or Class C.