beautypg.com

Features – Kidde KN-COSM-IB User Manual

Page 7

background image

• Voice Message System that alerts user to the following

conditions:

– Only for smoke alarm Hush

System announces “HUSH MODE ACTIVATED” when
the unit is first put into HUSH Mode.

– Only for smoke alarm Hush

System announces “HUSH MODE CANCELLED” when
unit resumes normal operation after Hush Mode has
been cancelled.

– Only if button is pushed

System announces “CARBON MONOXIDE PREVIOUSLY
DETECTED” when the unit has detected CO
concentrations of 100 ppm or higher.

– System announces “PUSH TEST BUTTON” when the unit

is powered up, reminding user to activate the Test
Button.

• End of Life Hush. At end of product life, the button can be

pushed to silence the end of life "chirp" for approximately
3 days at a time, for a maximum of 30 days life extension.

• One “chirp” every 30 seconds coupled with a green LED flash

twice a second is an indication that the alarm is
malfunctioning. If this occurs call the Product Support Line at
1-800-880-6788.

• Test/Reset button performs functions.(See page 14).

• HUSH Control Feature that silences the unit during nuisance

alarm situations (see page 15).

• Peak Level Memory Feature which alerts user when the unit

has detected CO concentrations of 100 ppm or greater (see
page 16).

• Smoke Alarm Memory Feature that gives visual indication

when an alarm has sensed a hazardous condition.

• Green and red LED lights that indicate normal operation and

alarm status (see page 17 for details).

• Tamper Resist Feature that deters children and others from

removing the alarm (see page 17).

• Battery reminder flag that prohibits installation when batteries

are not present.

Features

5

2544-7201-00(KN-COSM-IBA)_V4a.qxd:_ 2013.7.1 2:44 PM Pag

This manual is related to the following products: