Operating instructions – Kidde KN-COPE-I User Manual
Page 21

Alarm/Peak Level Memory
If the green LED is blinking once every 16 seconds, the unit
has detected a hazardous condition. If the unit has detected
a CO level of 100 PPM or greater, pushing the Test/Reset
button will result in a voice message “Caution, carbon
monoxide previously detected”. Peak level also happens if
the unit detects smoke and then comes out of alarm.
However, there is no voice message if the unit is in peak
level due to smoke. When the Test/Reset button is pushed,
the unit will produce three rapid beeps. Pushing the
test/reset button resets the memory. It’s also reset when the
power is removed.
LED Indicator Operation
Red LED
The red LED will flash in conjunction with the alarm
sounder. Therefore, the red LED will flash during a smoke
alarm, a CO alarm, a low battery mode chirp and a unit
error mode chirp.
16
Operating Instructions
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH®
CONTROL FEATURE AND SOUND A CONTINUOUS
ALARM.
CAUTION: BEFORE USING THE ALARM HUSH® FEA-
TURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE
CERTAIN A SAFE CONDITION EXISTS.
Reset Feature
If the Smoke/CO Alarm is sounding a CO alarm, pressing
the test/reset button will initiate a test/reset. If the CO con-
dition that caused the alert continues, the alarm will reacti-
vate.
2528-7207-01(820-1669Rev.B).qxd:_ 2013.5.10 4:42 PM Page 21