Step 4: Testing the Alarm

CAUTION: Due to the loudness (85 decibels) of the
alarm, always stand an arms length away from the
unit when testing.

The test/reset button has six purposes. It tests the unit’s
electronics, resets the CO alarm, activates the HUSH fea-
ture, (As well as Low Battery HUSH and End of Life Hush)

and activates the Peak Level Memory Feature.

After installation, TEST THE UNIT’S ELECTRONICS by press-
ing and releasing the test/reset button. You will hear the
following sequence of “beeps” and verbal warnings:

Three long beeps

Verbal warning: “FIRE! FIRE!”
Three long beeps.

Four quick beeps

Verbal warning: “WARNING! CARBON MONOXIDE”

Four quick beeps

Weekly testing is required! If at anytime it does not perform
as described, verify power is connected correctly and that
the battery doesn’t need replacing. Clean dust and other
buildup off the unit. If it still doesn’t operate properly call
the Product Support Line at 1 (800) 880 6788.

Interconnect Feature
Your Combination Smoke/CO Alarm can be interconnected to
other multiple station Kidde, Nighthawk, Kidde/Fyrnetics, and
Kidde/FireX products:

• When compatible smoke alarms and heat alarms are inter-

connected to your Smoke/CO Alarm, they will only respond
to a smoke related event.

• When mixing compatible models with battery backup with

models without battery backup, be advised that the models
without battery backup will not respond during an AC
power failure.

• This unit is only approved to interconnect with other

Kidde/Nighthawk products. It is NOT approved to intercon-
nect with any other brand of detection product.

14