beautypg.com

Nuisance alarms – Kidde P3010L User Manual

Page 6

background image

GENERAL VISUAL AND AUDIBLE INDICATOR OPERATION

Red LED Indicator: The red LED will blink in conjunction with the alarm sound.
Therefore, the red LED will blink during a smoke alarm, a low battery mode
chirp, a unit error mode chirp or at end of unit life.

Fault Mode Indicator: These alarms monitor strategic functions of internal
electronics and sensors. If a problem is detected the alarm will enter a fault
mode. If this occurs the alarm will produce a single “chirp” approximately every
30 seconds and blink the Red LED 2-12 times. If this should occur call Kidde
Customer service at 1-800-880-6788.

End of Unit Life Indicator: Ten years after initial power-up, this unit will
“chirp” twice every 30 seconds to indicate that it is time to replace the alarm.

This alarm has End of Life Hush

®

which allows you to silence the trouble chirp for

three days giving you extra time to replace the unit at a more convenient time.

To activate, press the Test/Hush button. While in the End of Life Hush

®

mode,

the alarm will still detect Smoke.

The End of Life signal can be reset a maximum of 10 times for a total of 30
days. After 10 resets the end of life signal can no longer be silenced and the
alarm must be replaced immediately.

7. NUISANCE ALARMS

This Smoke alarm is designed to minimize nuisance alarms. Cigarette smoke will
not normally cause the unit to alarm, unless the smoke is blown directly into the
alarm. Combustion particles from cooking may set off the alarm if it is located
too close to a cooking appliance. Large quantities of combustible particles are
generated from spills or when broiling. Using the fan on a range hood which
vents to the outside (non-recirculating type) will also help remove these combus-
tible products from the kitchen.

If the alarm does sound the smoke alarm pattern of 3 long beeps, check for fires
first. If a fire is discovered, get out and call the fire department. If no fire is pres-
ent, check to see if one of the reasons listed in “Locations to avoid” may have
caused the alarm.

SMART HUSH

TM

CONTROL: The SMART HUSH

TM

feature has the capability of

temporarily desensitizing the alarm circuit for approximately 10 minutes. This
feature is to be used only when a known alarm condition, such as smoke from
cooking, activates the alarm. The smoke alarm is desensitized by pushing the
Test/Hush button on the smoke alarm cover. If the smoke is not too dense, the
alarm will silence immediately and the red LED blinks every 10 seconds. This
indicates that the alarm is in a temporarily desensitized condition.

Model P3010B will issue a voice prompt stating “Hush Mode Activated.”
Model P3010H will turn off the amber safety light.

The smoke alarm will automatically reset after approximately 10 minutes and
sound the alarm if particles of combustion are still present.

Model P3010B will issue a voice prompt stating “Fire-Fire.”

The SMART HUSH

TM

feature can be used repeatedly until the air has been

cleared of the condition causing the alarm. Pushing the Test/Hush button on the
alarm will end the temporarily desensitized period.

Model P3010B will issue a voice prompt stating “Hush Mode Cancelled” after
the Test/Hush button has been pressed.

If the smoke is not too dense, after ten minutes the alarm will return to normal
operation.

Operational

Mode

Visual

Indications

Audible

Indications

Note:

Normal Opera-

tion

Blink once every 60

seconds

None

LED will flash every 60 seconds for

10 minutes following power on or

reset. After initial 10 minutes,

LED will flash once every

10 minutes

Test/Hush But-

ton Press

Blink with each alarm

pattern

Two sets of 3 long

beeps

Test/Hush button press will initiate

test sequence

Voice “Fire-Fire”

announced

Model P3010B

with Voice

Smoke Alarm

Hush

Blink once every 10

seconds

None (smoke alarm

silenced)

Alarm hush feature silences smoke

alarm for approx. 10 minutes. See

page 13 for additional instructions.

Low Battery

Blink once every 30

seconds

Chirp every 30

seconds

Remove, turn off and

replace alarm

Voice “Low Battery”

announced

Model P3010B with Voice

Fault Mode

Fault code (2-12

flashes every 30

seconds)

Chirp every 30

seconds

Remove, turn off and

replace alarm

End of Unit

Life*

2 blinks every 30

seconds

2 chirps every 30

seconds

Remove, turn off and

replace alarm

End of Unit Life

Hush

None

None (End of Life

chirps silenced)

* End of life hush feature. Silences end of life indication 3 days at a time for

a maximim of 30 days.