• In insect-infested areas.
• Smoke alarms should not be installed within 3 ft (.9m) of the
following: the door to a kitchen, the door to a bathroom con-
taining a tub or shower, forced air supply ducts used for heating
or cooling, ceiling or whole house ventilating fans, or other high
air flow areas.
• Kitchens. Normal cooking may cause nuisance alarms. If a
kitchen alarm is desired, it should have an alarm silence feature
or be a photoelectric type.
• Near fluorescent lights. Electronic “noise” may cause nuisance
alarms.
• Smoke alarms are not to be used with detector guards unless
the combination (alarm and guard) have been evaluated and
found suitable for that purpose.
3. INSTALLATION INSTRUCTIONS
CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOV-
ABLE!
1. Remove the mounting plate from the back of the alarm by hold-
ing the mounting plate and twisting the alarm in the direction
indicated by the “OFF” arrow on the alarm cover.
FIGURE 4
When mounting
in a hallway,
attach mounting
plate to ceiling
approximately as
shown.
When wall mount-
ing, mount flat side
to the wall and
rotate mounting
plate approximately
5º to the right as
shown.
Install
Remove
5º
FIGURE 5
FIGURE 6
FIGURE 7