Hxjz-877 parameters setting, Parameters default value, Channel and frequency list – Hexin Technology HXJZ-877 2000m-3000m Low Power RS-232/RS-485/TTL to RF Wireless Module User Manual
Page 6
HXJZ-877 Mini Power Wireless Module User’s Manual
Awaken from Air, you can transmit some useless data firstly.
HXJZ-877 parameters setting
HXJZ-877 have one interface of TTL、RS232、RS485, You should say clearly which interface you need
when place an order.
HXJZ-877 main parameters: COM baud rate and verify ,RF baud rate, Channel and frequency.
You can change these parameters by our RF Module soft. Wh en RF baud rate is faster than COM baud
rate,One frame Can transmit limitless data. When RF baud rate is not faster than COM baud rate ,One frame
Can transmit 255 bytes most. You can set the rate according your need.
The general Power supply is 5V DC.
Two HXJZ-877 communication must have condition as follow:
1. Their channels (i.e. frequency) are the same.
2. Their RF rates are the same.
3. RF Module Com baud rate and verify is comply with its equipment or PC.
Parameters default value:
Channel: 5
Interface speed rate:9600BPS
Interface verify:none
Speed rate in air:9600BPS
Channel and frequency list
Channel
Frequency
Channel
Frequency
1
430.2000MHZ
9
458.5250MHZ
2
431.4288MHZ
10
459.1250MHZ
3
431.7360MHZ
11
459.5250MHZ
4
430.5072MHZ
12
460.1250MHZ
5
434.6940MHZ
13
460.5250MHZ
6
434.2332MHZ
14
461.1250MHZ
7
433.1580MHZ
15
461.5250MHZ
8
433.9260MHZ
16
462.1250MHZ