Material safety data sheet – Pro-Link StandardAire Burst Refills SA23-30R EN User Manual
Page 2

MATERIAL SAFETY DATA SHEET
___________________________________________________________________________________ 
Date of last change 08/25/2011 
Page 2 of 4
containers to prevent build up if exposed to extreme 
temperatures. Full protective equipment including self 
contained breathing apparatus should be worn in a fire 
involving this material. 
Flammability
Flammable
If yes, under which conditions?
Excessive heat, sparks and open flame
Extinguishing media
Water, Carbon Dioxide, Dry Chemical, Foam
Upper Flammable limit (% by volume)
23.5
Lower Flammable limit (% by volume)
1.2
Explosion Data – Sensitivity to static 
discharge 
Not Applicable
Explosion Data – Sensitivity to impact
Not Applicable
Hazardous combustion – Products
Hygdrocarbon fumes and smoke. Carbon Monoxide where 
combustion is incomplete. 
Aerosol flame projection – classified as:
15 – 45 cm
Aerosol flame projection – flashback:
None
Flash Point (ºC), Tag Closed-Cup 
(Concentrate) 
Lowest known value is acetone @ -18ºC
 
 
 
 
Leak/spill 
Remove all sources of ignition. Use an inert absorbent material, and 
non-sparking tools. Ventilate area. Prevent from entering a 
watercourse. 
 
 
 
 
Storage Needs 
Keep away from heat, sparks, and open flames 
 
Engineering controls
Ventilation – Local (Mechanical if used indoors on a continuous basis) 
 
Handling Procedures and 
Equipment 
Store in a cool, well ventilated area not to exceed 50 deg. C
Synergistic Materials
None known
 
 
 
 
Gloves / Type 
Not normally required 
 
Respiratory / Type
Not normally required 
 
Eye / Type
Safety Glasses 
 
Footwear / Type
Not normally required 
 
Other / Type
Not required
6.
ACCIDENTAL RELEASE MEASURES
7.
HANDLING & STORAGE
8.
EXPOSURE CONTROLS / PERSONAL PROTECTION