Material safety data sheet – Pro-Link StandardAire Burst Refills SA23-30R EN User Manual
Page 2

MATERIAL SAFETY DATA SHEET
___________________________________________________________________________________
Date of last change 08/25/2011
Page 2 of 4
containers to prevent build up if exposed to extreme
temperatures. Full protective equipment including self
contained breathing apparatus should be worn in a fire
involving this material.
Flammability
Flammable
If yes, under which conditions?
Excessive heat, sparks and open flame
Extinguishing media
Water, Carbon Dioxide, Dry Chemical, Foam
Upper Flammable limit (% by volume)
23.5
Lower Flammable limit (% by volume)
1.2
Explosion Data – Sensitivity to static
discharge
Not Applicable
Explosion Data – Sensitivity to impact
Not Applicable
Hazardous combustion – Products
Hygdrocarbon fumes and smoke. Carbon Monoxide where
combustion is incomplete.
Aerosol flame projection – classified as:
15 – 45 cm
Aerosol flame projection – flashback:
None
Flash Point (ºC), Tag Closed-Cup
(Concentrate)
Lowest known value is acetone @ -18ºC
Leak/spill
Remove all sources of ignition. Use an inert absorbent material, and
non-sparking tools. Ventilate area. Prevent from entering a
watercourse.
Storage Needs
Keep away from heat, sparks, and open flames
Engineering controls
Ventilation – Local (Mechanical if used indoors on a continuous basis)
Handling Procedures and
Equipment
Store in a cool, well ventilated area not to exceed 50 deg. C
Synergistic Materials
None known
Gloves / Type
Not normally required
Respiratory / Type
Not normally required
Eye / Type
Safety Glasses
Footwear / Type
Not normally required
Other / Type
Not required
6.
ACCIDENTAL RELEASE MEASURES
7.
HANDLING & STORAGE
8.
EXPOSURE CONTROLS / PERSONAL PROTECTION