READY

ON/OFF

TEMP

AERATION

OTHER FEATURES

LED SCREEN DISPLAY

When the unit is on and not in programming mode, the UCM will stay on and the LED screen will

display the current tank temperature. The factory setting is 204ºF. In the UCM programming, there is

an option to change the screen display to read HOT instead of the set point temperature. You may also

change the temperature units from Fahrenheit to Celsius.
To Change the LED To Read HOT:
1. Press the left TEMP button and hold down for 5 seconds. The F will start flashing.
2. Continue holding the TEMP button, at the same time, press and hold the ON/OFF button for 5

seconds.

3. Release both buttons. The program is now changed and the LED screen will display HOT.
4. While in the HOT display, pressing the TEMP button for 1 second will display the tank temperature.

To Change the LED To Read In Celsius:
NOTE: When the LED screen is in the HOT display mode, you cannot switch between Farenheit and

Celsius. The LED screen must be in the Temperature display mode.
1. Press and hold down the TEMP button for 10 seconds. The temperature reading will change to

Celsius.

2. Release the TEMP button. The LED screen will display the temperature in degrees Celsius (default is 96ºC).

AERATOR
The aerator pump will automatically come on every 30 minutes. Aeration is factory set to run for 5 seconds. When the aeration is running, the display

shows the LED bars chasing from left to right.

ERROR CODES
ERR1

= Overflow. Water level error.

ERR2

= Open sensor. Break in temperature thermistor circuit.

UNIVERSAL CONTROL MODULE (UCM)

A

FUNCTION

1. Press TEMP button for 1 second to check the set point

temperature.

2. Press TEMP button for 3 seconds to enter heating tank

temperature programming mode. The temperature in the

heating tank is adjustable from 140º to 210º F.

To change temperature setting:
a. Press

to increase at 2º increments.

b. Press

to decrease temperature.

c. Press

to set and exit programming.

B

FUNCTION

1. Press the AERATION button to pump air through the water in the heating tank.
2. Aerator pump will run as long as you hold down the button. Release button to stop.

I/O

FUNCTION

1. ON/OFF button. Press once to activate control panel.
2. ON/OFF button used to set and exit programming.

PROGRAMMING

2

READY

ON/OFF

TEMP

AERATION

READY

ON/OFF

TEMP

AERATION