beautypg.com

Program menus – Wilbur Curtis ALPHA 6GTN User Manual

Page 3

background image

3

2

Cold Brew Lock . . . (Factory set to 15º) Press to select, < or > to select desired setting (CBL 5, 15 or OFF), to set.

The Cold Brew Lock feature allows the brewer to brew at three different temperature levels from the actual set point. The first setting is within 5 degrees of set

point, next is within 15 degrees of set point, OFF is within 30 degrees of set point for the Ready to Brew message, however it will brew at any temperature.

This feature will operate after initialization to set temperature after the rear standby toggle switch is reset to ON.

Master Reset Press to display Are You Sure? Then < for Yes, > for No. Brewer factory defaults are then reset.
Service Call (Phone number Factory set to [800] 995-0417) Press
to display number and change number or < to move place and EX to exit when

complete This number will be displayed during a Heating system SENSOR ERROR or during a WATER ERROR.
Access Code (Factory set to 1-2-3-4) Press
to display number and change number, (the number can be change 1 to 4) or < to move place and ex to exit

when complete.
Banner Name (Factory set to CURTIS) Press
to display letters and change letters or < to move place and EX to exit when complete. This feature allows

up to 14 letters to be programmed for company name or regional name. Programming all blanks disables Banner Name.
Warmers Auto OFF (Factory set to Disable) Press
to Select. Press < or > to move to desired time and then to set. Timer is programmable from 2 to 4

hours in one hour increments or OFF.
P-Maintenance (Factory set to OFF) Press
to Select, Set gallons brewed to indicate P-Maintenance. Press < or > to adjust from Off to 3000 gallons.

Press to exit.
Beeper On/Off (Factory set to ON) Press
to display ON or OFF. Pressing either < or > toggles between on and off. to set.
Pulse Brew (Factory setting OFF)
Press to select, < or > to select OFF or one of five pulse patterns (A to E) .
Guidelines for Pulse Brew:

This feature allows tuning of the coffee flavor. The pot level should always be set first with this option OFF. Depending on your grind profile and water conditions,

the five Pulse Brew options help “tune” or change the coffee flavor. Filter Pack type coffees typically extract better with the A and B pulse setting. Decaffeinated

coffees typically extract better with the B pulse setting. High-Yield coffees typically extract better with the C pulse setting. Of course, any of the A, B or C settings

may be used to suit your taste profile. There are two additional settings (D and E) that allow you to manually set the ON TIME pulses and OFF TIME.

If Pulse Brew is selected (ON), Cold Brew Lock is set to Delta 1 within 5ºF of set point and Cold Brew Lock disappears from the list of program selec-

tions. When Pulse Brew is ON, Pre-infusion disappears from the list of program selections.

Display Brew Time (Factory set to ON). Press to display ON or OFF. Pressing either < or > toggles between on and off. to set. When on, the Display

Brew Time feature allows you to see the remaining time in the brewcyle counting down.
Drip-Out Mode (Factory set to 2 min)
Press to select. Press > to increase time (to a maximum of 5 minutes) or < to decrease the time and turn OFF.

Time counts up in 5 second increments. Press to set.
Model Select Press
to select, < or > to select model. The selections are: ALPHA-1, ALPHA-2, ALPHA-3/4/5, Airpot Brewer, Thermo-Alpha (for the D60GT).

Press to set. When the Model Select feature is changed, all settings are reset to the defaults of the newly selected model.
Exit Press
to select, exits program mode and returns unit to operation.

Warmer Temperature Control

Turn on brewer at the control panel ON/OFF button. Warmer button should be OFF (LED off). Press and hold desired WARMER button. Screen will display cur-

rent setting in % of power. Press < or > to increase or decrease power to warmer (50% to 100% in 10% increments). Press to set.

Tank Temperature Check

Turn on brewer at the control panel ON/OFF button. Press and hold 3 button (see illustration, page 2) for 5 seconds. Water Temperature will be displayed.

The temperature will not display while the unit is in the process reheating.
NOTE: Alpha 3GT ONLY; when checking tank temperature, first make sure REAR warmer is ON (red LED on) and then press 3 for 5 seconds to display

tank temperature.

Brew Volume – Easy Access

Units produced beginning January 2008 can be easily adjusted from the front panel. Written into the software on the Alpha GT UCM, is a feature to access the

brew volume without entering the program mode.
The UCM must be on. To adjust the ALP1GT models, press and hold down the center, Select button 2 . The screen will read

pressing < or >

will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.
On any multi-station Alpha (ALP2/3/4/5/6GT): Press the center Select button 2 twice, with the second press hold down the button for around five [5] seconds.

The screen will display

pressing < or > will adjust the brew volume up or down, ± 20 oz, in 1 ounce increments.

Vol. Adj. < -0 > Oz.

- Select +

Vol. Adj. < -0 > Oz.

- Select +

PROGRAM MENUS