beautypg.com

Vermont castings vigilant – Vermont Casting 2310 User Manual

Page 15

background image

15

Vermont Castings Vigilant

2000898

connector enters the chimney. Follow all the guidelines
for installing a chimney connector into a freestanding
masonry chimney, and watch these additional points:

ST695

Vigilant

above fireplace

8/8/01

VIGILANT�

Thimble Sleeve

Mantel

Bottom Heat

Shield

Damper - closed

and locked

ST695

Fig. 20 In this installation the chimney connector is attached
to the chimney above the fireplace.

• If there is a combustible mantel or trim, check the

stove and chimney connector clearances in the
Clearance Chart. Use the necessary combination of
mantel, trim, and connector heat shields to provide
the required clearances.

• Double check connector clearance from the ceiling.
• The fireplace damper must be closed and sealed

to prevent room air from being drawn up the flue,
reducing the draft. However, it must be possible to
re-open the damper to inspect or clean the chimney.

Through a fireplace
When installed through a fireplace opening, the chim-
ney connector goes back from the stove, enters the
fireplace cavity, turns upward, and passes through the
fireplace damper opening and smoke chamber, and
finally to the chimney flue. Watch these points:
• If there is a combustible mantel or trim, check the

stove and chimney connector clearances in the
Clearance Chart. Use the necessary combination of
mantel, trim, and connector heat shields to provide
the required clearances.

• When passing the chimney connector through the

damper opening it may be necessary to “ovalize” the

ST696

fireplace

flex connector

8/8/01

VIGILANT�

Flex Connector

Mantel Shield

Fireplace Adapter

Bottom

Heat

Shield

ST696

Fig. 21 In this installation, the chimney connector enters the
fireplace opening and then connects to chimney.

connector pipe. Do not make the narrowest width
less than 5¹⁄₂".

• The damper should be removed if possible, or

sealed in the open position if removal is impossible.

• A seal must be provided so that room air is not

drawn into the fireplace and up the chimney, reduc-
ing draft. The Vermont Castings Flex Connector
System provides a convenient method for making
the required seal and offers a flexible stainless steel
chimney connector which can be bent to allow pas-
sage through most narrow damper openings.

NOTE: Do not vent your Vermont Castings stove
into a factory-built (zero-clearance) fireplace. Zero-
clearance fireplaces and their chimneys are specifi-
cally designed as a unit for use as fireplaces. It may
void the listing or be hazardous to adapt them for
any other use.