Vermont Castings Vigilant

2000898

Vigilant II Clearance Chart

Unprotected Surfaces

Side Rear Corners

Side Rear Corners

Stove in Corner

Stove Installed Par-

allel to Wall

Stove in Corner

Stove Installed Par-

allel to Wall

Stove Clearance

Protected Surfaces

Chimney Connector Clearance

Single-wall
connector
No heat shields

Single-wall connector
Rear exit,
Rear heat shield

Double-wall connector
Top exit
Rear heat shield

Single-wall connector
Top exit
Rear and chimney
connector heat
shields

1

Single-wall connector
No connector heat
shields

Single-wall connector
Connector heat
shields installed

Double-wall
connector

All Installations

48” (1219 mm)

Clearance to Combustibles in Front of Stove

1. A ceiling heat shield, 24” (610 mm) in diameter and suspended 1” (25 mm) from the ceiling, must surround the chimney con-

nector in installations in which the chimney connector penetrates the ceiling. The chimney connector shield extends only to

24” (610 mm) above the flue colllar.

2. The ceiling heat shield required when the chimney connector shields are used should meet the wall protector. This will require

trimming the ceiling shield along the line of intersection with the wall protector.

All Installations

All Installations

18”

(457 mm)

20”

(508 mm)

16”

(406 mm)

7”

(178 mm)

13”

(330 mm)

9”

(229 mm)

18”

(457 mm)

13”

(330 mm)

16”

(406 mm)

7”

(178 mm)

11”

(279 mm)

9”

(229 mm)

18”

(457 mm)

13”

(330 mm)

N/A

7”

(178 mm)

11”

(279 mm)

N/A

15¹⁄₂”

(394 mm)

13”

(330 mm)

16”

(457 mm)

7”

(178 mm)

10¹⁄₂”

(267 mm)

9”

(229 mm)

17” (432 mm)

11” (279 mm)

12” (305 mm)

9” (229 mm)

9” (229 mm)

2

7” (178 mm)