Petsafe Innotek Smart Dog® Rechargeable In-Ground Pet Fencing System User Manual
Page 20

The leads, trainers, flags and the collar receiver signals are all training clues for your dog. During the last three weeks of
training --one by one--all but the collar receiver will be removed.
As the training clues are removed it is essential that you continue to use distractions to make sure your dog retreats from
the unmarked boundary.
The stimulation teaches the consequences of the improper response. Know your dog and what tempts him. Gradually extend
the amount of unsupervised freedom, and finally remove the flags when you are confident that your dog is fully trained.
Innotek, Inc. (800)-826-5527 www.innotek.net
TROUBLESHOOT-
Transmitter Problems:
Possible Solutions:
4. No status light on the transmit-
ter and the alarm is on. (System
on battery backup power.)
(continued)
5. Transmitter status/alarm priori-
ty sequence.
Collar Receiver Problems:
1. Collar Receiver does not
appear to be operating in con-
tainment field area.
2. Collar Receiver is not taking a
charge.
3. Receiver is not working and
case is damaged or "chewed" by
dog.
4. SD-2200 system only. If the green power light on the lightning
protector is not illuminated, unplug the lightning protector and plug
the power adapter directly into the 110-volt outlet. If the transmitter
operates when bypassing the lightning protector, contact Innotek
for a warranty replacement lightning protector. Do not use the sys-
tem until a replacement lightning protector has been provided.
5. If possible, check the voltage of the power adapter using a digi-
tal multimeter. It should read greater than 24 volts AC.
Under multiple operating/fault status conditions, the operating/fault
alarm priority sequence is as follows:
1. Boundary wire broken or disconnected.
2. AC power disconnected operating on battery backup power.
3. Receiver charging.
4. Receiver charge reminder.
5. Backup batteries low.
Possible Solutions:
1. Verify the transmitter is turned on and the status light is solid
green.
2. Check the collar receiver for a green flashing indicator light. If
light is flashing red or there is no light, recharge battery. See
Section 5.B.4, page 14.
3.Perform the field width test of Section 4.H.3 page 12 using the
test light and determine if the test light is illuminating.
4.Perform System Test procedure to determine which component
is malfunctioning. See Test Procedures, page 20.
1. Check that the collar is proper positioned in the charging cradle
on top of the transmitter. When properly positioned the transmitter
status light will flash green and a high frequency charge tone will
be heard.
2. Check that the adapter (and lightning protector, if applicable)
are plugged in and either the boundary loop wire or a short test
loop wire is connected. A loop wire must be connected for the
charger to function.
Contact Innotek to purchase a new collar receiver.
20.