Nextteq Irritant Smoke Tube Kit for Respirator Fit Testing and Airflow Indication User Manual
Page 25

Page 22
Nextteq Irritant Smoke Tube Kit Manual
The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.
Nextteq is Gastec’s exclusive U.S. master wholesale distributor.
Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.
P/N 9505 Rev F 8/09
MSDS
Get medical help in case of a large area of contact or if irritation
persists.
Inhalation: Remove test subject to fresh air. Restore and/or support
breathing as necessary. Provide oxygen therapy for persistent
coughing or if breathing is difficult. Keep subject warm and at rest.
Get medical help.
Swallowed: If swallowed, get medical help immediately.
aSSIStanCe: IF THE USER IS CONFUSED ABOUT THE PROPER
USE OF THE SMOKE TUBE / GENERATOR OR ANY INSTRUCTIONS,
WARNINGS, LABELS, OR THE MANUAL, PRIOR TO USING
THIS PRODUCT THE USER SHOULD CONTACT NEXTTEQ FOR
ASSISTANCE. NEXTTEQ CAN BE CONTACTED AT ONE OF THE
FOLLOWING TELEPHONE NUMBERS: TOLL FREE 877-312-2333 OR
LOCAL NUMBER 813-249-5888.
______________________________________________________
part 6 - reactivity Information
______________________________________________________
Stability: SnCl
4
decomposes upon exposure to moist air or
water. HCl is a stable compound. It does not undergo hazardous
polymerization; however, HCl can catalyze polymerization of other
compounds.
Conditions to avoid: Reacts with turpentine, alcohols, and amines
causing a potential fire hazard. Incompatible materials include alkali
compounds, amines, metal oxides, hydroxides, copper, brass, zinc,
other metals, turpentine, and alcohols. Mixing with alkali metals may
result in an explosion.
hazardous decomposition products: When heated to
decomposition, the smoke tubes will emit chloride fume.