Nextteq Irritant Smoke Tube Kit for Respirator Fit Testing and Airflow Indication User Manual
Page 11

Page 8
Nextteq Irritant Smoke Tube Kit Manual
The Gastec Irritant Smoke Tube (Part Number 9501) is manufactured by the Gastec Corporation.
Nextteq is Gastec’s exclusive U.S. master wholesale distributor.
Tel: 813-249-5888 Toll free: 877-312-2333 Fax: 813-249-0188 Toll free: 877-312-2444 www.nextteq.
P/N 9505 Rev F 8/09
Warnings
A. If inhaled and repeated coughing or trouble breathing
occurs, immediately remove test subject to fresh clean air.
Restore and support breathing as necessary.
B. If coughing or breathing difficulty persists, immediately
provide oxygen and immediately contact a physician.
C. If smoke contacts eyes, immediately flush eyes with
copious amounts of clean running water for fifteen (15)
minutes, including under eyelids, and immediately contact
a physician.
D. If smoke contacts a large area of skin, contacts skin for
a prolonged period, or if irritation persists, immediately
flush affected area with copious amounts of clean running
water for fifteen (15) minutes and immediately contact
a physician.
19. Do not use this product for Respirator Fit Testing or Sensitivity
Check if any of the following conditions are present:
A. The test subject has a pre-existing respiratory,
cardiovascular, or bronchial medical condition.
B. The test subject is under a physician’s care for a res-
piratory, cardiovascular, or bronchial ailment; sinus,
nasal, or ear infection; or impaired immune system;
or asthma.
C. The test subject is hypersensitive or allergic to stannic
chloride, stannic oxide, hydrogen chloride, tin
tetrachloride, tin compounds, or metal chloride.
D. The test subject has failed the medical evaluation
specified by OSHA 29 CFR 1910.134.