beautypg.com

Vi - troubleshooting, Cont.) – Bradford White IGE-199R-10N User Manual

Page 31

background image

31

Nature of Fault

Examination

Point

Diagnostic Point

Values

Y/N

Action

Service

Procedure

Error code "11"
displayed on
digital monitor.

5. Check ignition
module.

1. Measure voltage
between grey ~ grey of
connector F

8

(ignition

module).(See page 37)
2. # Remove connector
F

8

and measure the

resistance between
ignition module and
terminals. (See page 37)

90 ~ 110 VAC

Is resistance >1MΩ?

Yes

No

Yes
No

Go to B-5-2

Replace PCB

Go to B-5-3
Adjust/
Replace
ignition
module

IGE – 2

IGE – 4

3. Check if unit is
sparking.

Is the ignition
module sparking?

Yes

No

Go to B-6

Adjust/
Replace
electrode

6. Check main gas
solenoid valve (SV0)
Error code 71

1. # Disconnect the main
solenoid valve connector
E from the PCB, and
measure the resistance
between pink ~ black

(SV0)

2. Measure voltage
between pink ~ black of

SV0 connector.
(See page 38)

1.7 ~ 2.1KΩ

80 ~ 100 VDC

Yes

No

Yes
No

Go to B-6-2

Replace gas
valve

Go to B-7
Replace PCB

IGE – 9

IGE – 2

7. Check solenoid
valve (SV1)

1. # Disconnect
connector E from the
PCB. Measure resistance
between yellow ~ black

of (SV1).

2. Measure voltage
between yellow ~ black

of SV1 connector.
(See page 38)

1.7 ~ 2.1KΩ

80 ~ 100 VDC

Yes

No

Yes
No

Go to B-7-2

Replace gas
valve

Go to B-8
Replace PCB

IGE – 9

IGE – 2

8. Check
changeover solenoid
valve (SV2)

1. # Disconnect
connector E from the
PCB. And measure
resistance between blue

~ black (SV2)

2. Measure the voltage
between blue ~ black or

SV2 connector.
(See page 38)

1.7 ~ 2.1KΩ

80 ~ 100 VDC

Yes

No

Yes
No

Go to B-8-2

Replace gas
valve

Go to B-9
Replace PCB

IGE – 9

IGE – 2

Error code "14"
displayed on
digital monitor

9. Check thermal
fuse

10. Check overheat
(remaining flame) bi-
metal switch

1. # Disconnect
connector B

3

and C

3

measure resistance
between red ~ red.

2. # Disconnect OHS
(remaining flame) bi-
metal switch festoon
terminal B

3

and C

3

, and

measure resistance
between terminal on
switch. (See page 40)

Is resistance < 1Ω?

Is resistance < 1Ω?

Yes

No

Yes

No

Go to B-10
Replace
thermal fuse

Replace PCB

Replace
remaining
flame bi-metal
switch

IGE – 11

IGE – 2

VI - TROUBLESHOOTING

(cont.)

Troubleshooting Flow Chart

BEFORE CARRYING OUT CHECKS MARKED WITH

A # SIGN, DISCONNECT THE POWER SUPPLY.