Vi - troubleshooting, Cont.) – Bradford White IGE-199R-10N User Manual

Page 30

background image

30

Nature of Fault

Examination

Point

Diagnostic Point

Values

Y/N

Action

Service

Procedure

2. Measure the voltage
at connector F with
appliance power supply
on.

F – Black ~ White

100 ~ 120 VAC

F

7

– Blue ~ Brown

100 ~ 120 VAC

Are values within
those specified at
left.

Yes

No

Go to A – (7)

Replace
transformer

IGE – 7

7. Check remotes (s)
(where connected.)

Measure voltage
between remote control
terminals at D.

11 ~ 13 VDC Digital

Yes

No

Check cable
for shorts or
broken wires.
Replace
remote
control.
Replace PCB.

IGE – 2

B. Digital monitor
lights up, but
combustion does
not commence.
(when remotes
are connected).

1. Check water flow
sensor.

1. Measure voltage
between red ~ black of

connector B

4

.

(See page 35)
2. Measure voltage
between yellow ~ black

at connector B

4

.

(See page 35)

11 ~ 13 VDC

4 ~ 7 VDC

Yes
No

Yes
No

Go to B–1-2
Replace PCB.

Go to B - 2
Replace water
flow sensor.

IGE – 2

IGE – 3

Error code "72"
displayed on the
digital monitor.

2. Check flame rod

# Measure resistance
between flame rod
terminal C

1

and earth.

(See page 36)

Resistance > 1MΩ?

Yes
No

Replace PCB
Replace flame
rod

IGE – 2

Error code "32"
displayed on the
digital monitor.

3. Check outgoing
water temperature
thermistor.

# Disconnect connector
B5 and measure
resistance.
Open circuit: > 1MΩ
Short circuit: < 1Ω
(See page 36)

Are values as shown
at left?

Yes

No

Replace water
temperature
thermistor.
Go to B - 4

IGE – 6

Error code "61"
displayed on the
digital monitor.

4. Check
combustion fan.

1. Check motor.
Measure voltage
between black ~ red at

connector A

1

.

(See page 37)

6 ~ 45 VDC (Fan on)

0 VDC (Fan off)

Yes
No

Go to B – 5-2
Replace PCB

IGE – 2

2. Check fan rotation
sensor. Measure voltage
between black ~ yellow

at connector A

1

.

(See page 37)

11 ~ 13 VDC

Yes
No

Go to B – 4-3
Replace PCB

IGE – 2

3. Measure voltage
between black ~ white
of connector A

1

.

(See page 37)

6 ~ 45 VDC

Yes
No

Go to B – 5
Replace fan

IGE – 5

VI - TROUBLESHOOTING

(cont.)

Troubleshooting Flow Chart

BEFORE CARRYING OUT CHECKS MARKED WITH

A # SIGN, DISCONNECT THE POWER SUPPLY.