Bradford White DH-75T-60FB-3X User Manual
Page 6
6
VENT-AIR INTAKE SYSTEM INSTALLATION
Tools Required For Vent-Air Intake Installation
The following minimum tools are required to properly install the vent-
air intake system. Note: Wall construction will determine tool usage.
• Tape Measure
• Drill
• 3/16 inch (4.5 mm) Diameter Drill Bit(s)
• 1/8 inch Diameter (3.0 mm) Drill Bit(s)
• Masonry Drill Bit(s) (For Poured Concrete, Concrete Block and
Brick Wall Construction)
• Reciprocating Saw w/appropriate Blade(s) (Dependent on Wall
Construction)
• Chisel
(For Poured Concrete, Concrete Block and Brick Wall
Construction)
• Hammer (For Poured Concrete, Concrete Block and Brick Wall
Construction)
• 1/4 & 5/16 inch Nut Drivers (Preferred) or Slotted Head
Screwdriver
• Phillips Head Screwdriver
WARNING
The vent-air intake system must be properly installed. Failure to
properly install the vent-air intake system could result in property
damage, personal injury or death.
Do not install any damaged vent-air intake system components.
Contact the manufacturer of the water heater for replacement parts.
IMPORTANT
When the following instructions specify, to seal a vent-air intake joint,
use only Loctite Ultra Blue 587 RTV Silicone sealant. A tube of Loctite
Ultra Blue 587 RTV Silicone sealant is supplied with each optional vent-
air intake kit. Make sure that all joints are completely sealed.
When drilling pilot holes for the #8 sheet metal screws through the six
(6) inch (15.2 cm) diameter components, be careful not to drill into the
inner four (4) inch (10.2 cm) diameter components.
WARNING
The vent-air intake terminal must be installed through an outside wall
in a horizontal position. This direct vent water heater is not designed
for through the roof vertical venting.