beautypg.com

Bradford White U-PDX-75S-55FR-3N User Manual

Page 35

background image

35

Venting continued-

TABLE 7

2” (5.1 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR

LOW GROUND CLEARANCE INSTALLATIONS

Terminating

# of Elbows

(excl. vent

term.)

Max Straight
Length
ft (m)

Min straight

Length

ft (m)

(2) 90

 Elbows with (1) 90

Elbow

1

20 (6.1)

5 (1.5)

(2) 90

 Elbows with (1) 90

Elbow

2

15 (4.6)

5 (1.5)

(2) 90

 Elbows with (1) 90

Elbow

3

10 (3.0)

5 (1.5)

TABLE 8

3” (7.6 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR

LOW GROUND CLEARANCE INSTALLATIONS

Terminating (Reduce 4”

to 3”) (Reduce 10.1 cm to

7.6 cm)

# of Elbows

(excl. vent

term.)

Max straight
Length
ft (m)

Min straight

Length

ft (m)

(2) 90

 Elbows with (1) 90

Elbow

1

40 (12.2)

10 (3.1)

(2) 90

 Elbows with (1) 90

Elbow

2

35 (10.7)

10 (3.1)

(2) 90

 Elbows with (1) 90

Elbow

3

30 (9.1)

10 (3.1)

(2) 90

 Elbows with (1) 90

Elbow

4

25 (7.6)

10 (3.1)

(2) 90

 Elbows with (1) 90

Elbow

5

20 (6.1)

10 (3.1)


HIGH ALTITUDE INSTALLATIONS FOR ELEVATIONS OVER 2,500
FEET (762 m)
ABOVE SEA LEVEL

The capacity of the induced draft blower declines with increasing altitude due to
a reduction in the air density. In order to assure safe and reliable performance
of the water heater, contact the supplier for high altitude kit.