beautypg.com

Bradford White TW4-75S-76B-3X User Manual

Page 6

background image

Specifications

Thermal well TCO Limit

Residential 188°F (87°C), Commercial 199°F (93°C)

Residential Temperature

Set Point Range

60°F (16°C) to 160°F (71°C) (Approximate temperatures)

Blower Temperature

Switch

Normally closed, opens @ 165°F (74°C), auto reset @ 130°F (54°C).

Blower

M2TW75 and TW475S Models:

115VAC, 60Hz, 3.1 amps, 3000 RPM, [email protected]" W.C.

Pressure switch

M2TW75 and TW475S Models:

Normally open, closes on vacuum increase @ -1.28, opens on vacuum decrease @ -1.25

Power supply

Dedicated 115VAC, 60 Hz, 15A

Approved Gas Type

Natural or Propane. Unit must match gas type supplied.

Venting System

Power vent through the wall or vertical through the roof

Approved Vent Materials PVC, CPVC or ABS

Gas Supply Pipe

Minimum 1/2" NPT (schedule 40 black iron pipe recommended)

Minimum Clearance

for Servicing

18" from top, 24" from front, 4" sides and rear.

Water Supply Pressure

150 PSI maximum allowable working pressure. Check local codes for supply pressure

Gas Pressure

5.0" W.C. min. for Nat gas, 11.0" W.C. min. for L.P. gas, 14.0" W.C. maximum (Nat. & L.P.)

Commercial Temperature

Set Point Range

80°F (27°C) to 180°F (82°C) (Approximate temperatures)

Page 6

6

This manual is related to the following products: