beautypg.com

Anode inspection and replacement – Bradford White TW4-75S-76B-3X User Manual

Page 31

background image

TTW SERVICE PROCEDURE XI

Anode

Inspection and replacement

Step 1.

Position on/off switch of gas control valve to the “OFF” position and unplug water heater from wall

outlet.

Step 2.

Turn off cold water supply to water heater. Connect hose to drain valve of water heater and route to an

open drain. Open a nearby hot water faucet to vent water heater for draining. Open drain valve of

water heater and allow water heater to drain to a point below the outlet connection nipple.

Step 3.

Disconnect outlet nipple from plumbing system.

Step 4

With an appropriate tool such as a pipe wrench, remove outlet nipple/anode from the water heater. Use

caution not to damage pipe threads.

Step 5.

Visually inspect outlet nipple/anode. Outlet nipple/anode should show signs of depletion, this is

normal. If depletion is ½ of the original anode diameter (approximately ¾” diameter), replacement is

recommended. If any of the steel core of the anode is exposed, replacement is recommended.

Step 6.

Upon completion of inspection or subsequent replacement, reinstall outlet nipple/anode into water

heater. Connect nipple to plumbing system, resume water supply and refill with water.

Step 7.

To resume operation, follow the instructions located on the lighting instruction label or the lighting

instructions located in the installation and operation manual.

Anode Inspection and Replacement

WARNING

Water Heater components and stored water may be HOT when performing the following

steps in this procedure. Take necessary precaution to prevent personal injury.

Page 31

31

This manual is related to the following products: