Troubleshooting continued-

LED Status

Control Status

Probable Cause

Six flashes, tw o

flashes, three
second pause

(Soft Lockout)

Damper test circuit not

w orking properly during

burner operation, system

auto resets after (5)

minutes

1. Damper not in proper position or
malfunctioning - damper moved from full
open position during run cycle
2. Obstructed venting
3. Faulty damper
4. Damper jostled during run cycle

Six flashes, three

flashes, three
second pause

(Soft Lockout)

Pilot flame extinguished,
system auto resets after

(5) minutes

1. Unstable pilot
2. Pilot tube block or restricted
3. Oxidation build-up on pilot electrode
4. Wire damage to pilot assembly or bad
connection at gas valve
5. Insufficient combustion air

Six flashes, four

flashes, three
second pause

Undesired false pilot flame

sensed, system auto

resets

Pilot valve stuck in open position

Seven flashes,

three second

pause

Flammable vapor sensor or

resettable thermal sw itch

fault detected, see

w arning label

1. Flammable vapor present
2. Flammable vapor sensor exposed to
excessive moisture
3. Flammable vapor sensor exposed to
extreme ambient temperature
4. Resettable thermal sw itch open

Eight flashes, one

flash, three

second pause

Flammable vapor sensor

out of specification,

possible short

1. Flammable vapor sensor out of
specification
2. Possible short in flammable vapor sensor
or resettable thermal sw itch w iring

Eight flashes,
three flashes,

three second

pause

Thermal w ell sensor

damaged or unplugged or

gas valve electronics fault

detected

1. Damage to thermal w ell w ires
2. Thermal w ell sensor resistance out of
range
3. Replace thermal w ell
4. Verify control is not w et or physically
damaged
5. Reset control on/off sw itch
6. Replace electronic module if 8-3 error
persists

Eight flashes, four

flashes, three
second pause

Gas valve fault detected

1. Verify control is not w et or physically
damaged
2. Reset control on/off sw itch
3. Replace gas control if 8-4 error persists

Fault Probable

Cause

Resettable Thermal Switch Tripped (Open)

1. Insufficient combustion air
2. Flammable vapor present