TROUBLESHOOTING

LED Status

Control Status

Probable Cause

None (LED not on

or flashing)

Electrical pow er not

present

Control pow er sw itch in " OFF" position.
Supply voltage interrupted.

One short flash

every four

seconds

Stand-by mode,

Thermostat is satisfied (no

faults)

Temperature demand is satisfied (no call for
heat)

Alternates bright

and dim

(heartbeat)

Thermostat calling for heat

(no fault)

Tank temperature below setpoint of
thermostat

Short flash once

every second

Weak pilot signal on last

call for heat

1. Unstable pilot
2. Pilot tube blocked or restricted
3. Oxidation build-up on pilot electrode
4. Wire damage to pilot assembly or bad
connection at gas valve

Tw o flashes,
three second

pause

Damper test circuit not

w orking

1. Damper not in proper position or
malfunctioning - stuck in open position
2. Obstructed venting
3. Faulty damper

Three flashes,

three second

pause

Damper test circuit not

w orking

1. Damper not in proper position or
malfunctioning - not reaching full open
position
2. Obstructed venting
3. Faulty damper

Four flashes,
three second

pause

Excessive tank

temperature, system must

be reset

1. Thermal w ell sensor out of calibration
2. Faulty gas valve

Five flashes,

three second

pause

False pilot flame present Pilot valve stuck in open position

Six flashes, one

flash, three

second pause

(Soft Lockout)

Failed to light pilot,

system resets after (5)

minutes

1. Unstable pilot
2. Pilot tube block or restricted
3. Oxidation build-up on pilot electrode
4. Wire damage to pilot assembly or bad
connection at gas valve

This manual is related to the following products: