SERVICE PROCEDURE AG-II

Pilot Assembly Inspection, Cleaning
and Replacement For Models Using

Honeywell Gas Control

R

IGNITER/ELECTRODE TESTING AND
REPLACEMENT

With the pilot not in operation (no pilot flame) the igniter and electrode circuit function can be observed by
opening the combustion chamber door and viewing whether there is a sparking action.

Step 1. Make sure the gas control is in the “OFF” position.

Step 2. Remove outer jacket door.

Step 3. Slide open or remove the inner

combustion chamber door.

Step 4. Depress the igniter button repeatedly while viewing

the spark through the open door of the combustion
chamber. If there is no spark proceed to Step 5.
If there is a spark, the igniter is OK.

Step 5. Remove the lead wire from the igniter at the connector

provided for this. Hold the igniter lead from the gas valve
close to an unpainted metal surface (such as the burner feedline)
and depress the igniter button (see Figure 15). If there is a spark the igniter is OK.
If no spark is present the igniter is not functioning and the gas control
must be replaced per Service Procedure AG-III page 18.

Repeatedly Depress

Igniter

Figure 15

Look for spark in

the gap

Page 11

11