beautypg.com

Bradford White 55X-80B-3X User Manual

Page 10

background image

SERVICE PROCEDURE AG-II

Pilot Assembly Inspection, Cleaning
and Replacement For Models Using

Honeywell Gas Control

R

Step 1. Turn off the gas supply to the water

Heater. Rotate gas control knob to the
“OFF” position.

Step 2. Remove outer jacket door.

Step 3. Remove burner assembly per

Service Procedure AG-IV page 20.

Step 4. Remove the pilot assembly from the burner assembly.

Step 5. Inspect the pilot assembly for the following:

a)Primary air opening for any blockage .
Must be free from any debris (dirt, lint, dust, etc.).
b) Kinks or cracks in the pilot tube. If found, the pilot
must be replaced.

Step 6. Inspect pilot orifice:

a) Remove 7/16” nut from the bottom of the pilot assembly.
b) Remove pilot tube and pilot orifice.
c) Inspect pilot orifice for blockage, must be free from any debris (dirt, lint, dust, etc.).
d) Reassemble pilot orifice and pilot tube to pilot assembly.

Step 7. Install pilot assembly to burner assembly using the screw from Step 4.

Step 8. Reinstall burner assembly per Service Procedure AG-IV page 22: Steps 10 through 12.

Step 9. To resume operation follow the instructions located on the lighting instruction label or the lighting

instructions located in the installation and operation manual.

Step 10. Check all gas connections for gas leaks using a soapy water solution.

PILOT ASSEMBLY INSPECTION,
CLEANING AND REPLACEMENT

Figure 12

Figure 13

Primary Air

Opening

Pilot Orifice

Page 10

10