beautypg.com

Bradford White 65T-65FB-3X User Manual

Page 26

background image

26

TROUBLESHOOTING CHART

LED Status

Control Status

Probable Cause

None (LED not on or
flashing)

Millivolt power is not
present. Light pilot.

1. Gas valve is functioning

normally

2. Gas valve is not powered.

Light pilot

One flash and three
second pause.

If set point knob is in
"PILOT" position then pilot
flame is detected.

(no

faults).

Gas valve is powered and waiting
for the set point knob to be turned
to a water temperature setting. If
the set point knob is at desired
setting the thermostat is satisfied.

LED strobe (two quick
flashes) and three second
pause

Thermostat calling for heat

(no faults)

Water heater operating normally.

LED on continuously.

Set point knob has been
recently turned to the
"OFF" position.

Set point knob was recently turned
to "OFF" position. Wait until LED
goes out before attempting to
relight

Two flashes and three
second pause.

Weak pilot flame detected.
System will reset when
pilot flame is sufficient.

1. Unstable pilot.
2. Pilot tube blocked or

restricted.

Three flashes and three
second pause.

Insufficient water heating.
System will reset.

1. Temperature sensor out of

calibration.

2. Possible

short.

Four flashes and three
second pause.

Excessive tank
temperature. System must
be reset.

1. Temperature sensor out of

calibration.

2. Faulty gas valve.

Five flashes and three
second pause.

Temperature Sensor fault.

1. Damage to the temperature

wire.

2. Temperature

sensor

resistance out of range.

3. Replace temperature sensor.
4. If temperature sensor

replacement does not correct
the problem; Verify control is
not wet or physically damaged

5. Turn set point knob to "OFF"

position. Turn set point knob
to "PILOT" position and light
pilot.

6. Replace gas valve if five flash

error persists.