WATER CONNECTIONS
Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE
MAIN WATER SUPPLY VALVE.
After shutting off the main water supply, open a faucet to relieve the water line
pressure to prevent any water from leaking out of the pipes while making the
water connections to the water heater. After the pressure has been relieved,
close the faucet. The COLD water inlet and HOT water outlet are identified on
the top of the water heater. The fittings at the cold water inlet and hot water
outlet are dielectric waterway fittings with ¾ inch NPT male thread. Make the
proper plumbing connections between the water heater and the plumbing
system to the house. Install a shut-off valve in the cold water supply line.
If sweat fittings are to be use, DO NOT apply heat to the nipples on top of
the water heater. Sweat the tubing to the adapter before fitting the adapter
to the water connections. It is imperative that heat is not applied to the
nipples containing a plastic liner.
FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED ¾ INCH X ¾
INCH TEMPERATURE AND PRESSURE RELIEF VALVE WILL
RELEASE THE MANUFACTURER FROM ANY CLAIM, WHICH MIGHT
RESULT FROM EXCESSIVE TEMPERATURE AND PRESSURES.
If this water heater is installed in a closed water supply system, such as the
one having a back-flow preventer in the cold water supply, provisions shall be
made to control thermal expansion. DO NOT operate this water heater in a
closed system without provisions for controlling thermal expansion. Your
water supplier or local plumbing inspector should be contacted on how to
control this situation
After installation of the water lines, open the main water supply valve and fill
the water heater. While the water heater is filling, open several hot water
faucets to allow air to escape from the water system. When a steady stream
of water flows through the faucets, close them and check all water
connections for possible leaks. NEVER OPERATE THE WATER HEATER
WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER.
CAUTION
WARNING
- 50T-65FB-3X U-65T-55FR-3N U-50T-55FR-3N 65T-65FB-3N 50T-65FB-3N PE-2-XR504T6FSX PE-4-5036FSX PE-4-40T6FSX PE-4-403S6FSX HE-4-50S6FSX HE-4-40S6FSX M-2-XR65T6FSX M-2-XR504T6FSX M-1-XR403S6FSX M-4-60T6FSX M-4-5036FSX M-4-403S6FSX M-4-40T6FSX M-4-30T6FSX M-I-60T6FSX M-I-504S6FSX M-I-50L6FSX M-I-5036FSX M-I-404T6FSX M-I-403S6FSX M-I-40T6FSX M-I-30S6FSX M-I-303T6FSX M-I-30T6FSX U2-XR-65T6FRN U2-XR-75S6RN U2-XR-504T6FRNU2-XR-504T6FRN U1-XR-403S6FRN U4-60T6FRN U4-5036FRN U4-40T6FRN U4-403S6FRN U4-30T6FRN U1-60T6FRN U1-5036FRN U1-403S6FRN U1-504S6FRN U1-404T6FRN U1-30T6FRN U1-50L6FRN U1-40T6FRN U1-30S6FRN PE-2-XR504T6FBN PE-4-5036FBN PE-4-40T6FBN PE-4-403S6FBN HE-4-50S6FBN HE-4-40S6FBN M-2-XR65T6FBN M-2-XR504T6FBN M-1-XR403S6FBN M-4-60T6FBN M-4-5036FBN M-4-403S6FBN M-4-40T6FBN M-4-30T6FBN M-I-60T6FBN M-I-504S6FBN M-I-50L6FBN M-I-5036FBN