Maintenance, Warning important – Bradford White 65T-65FB-3X User Manual
Page 23

23
MAINTENANCE
Water heaters are heat producing appliances. To avoid damage or injury there
shall be no materials stored against the water heater or vent-air intake system, and
proper care shall be taken to avoid unnecessary contact (especially by children)
with the water heater and vent-air intake system. UNDER NO CIRCUMSTANCES
SHALL FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT THINNER
BE USED OR STORED IN THE VICINITY OF THIS WATER HEATER, VENT-AIR
INTAKE SYSTEM OR IN ANY LOCATION FROM WHICH FUMES COULD
REACH THE WATER HEATER OR VENT-AIR INTAKE SYSTEM.
The following maintenance should be performed by a qualified service technician at the
minimum periodic intervals suggested below. In some installations, the maintenance
interval may be more frequent depending on the amount of use and the operating
conditions of the water heater. Regular inspection and maintenance of the water
heater and vent-air intake system will help to insure safe and reliable operation.
1. Annually check the operation of the thermostat.
2. The flow of combustion and ventilation air MUST NOT be restricted. Make sure
slots in jacket are open and unobstructed. Clear jacket slot openings of any dirt,
dust, or other restrictions. WARNING! The ventilation air system may be HOT.
3. At all times keep the water heater area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
4. Bi-annually conduct a visual check of the main and pilot burner flames to
determine that they are burning properly. See Burner Flame Check section of this
installation and operation manual. If sooting or other burner anomalies are
evident, shut down the water heater by turning off the gas per the instructions
listed in this manual or as listed on the water heater.
5. Annually remove the inner door and main burner assembly to clean orifices and
related parts of any dirt or other foreign material. Inspect the burner ports for
obstructions or debris and clean with a wire brush as needed. Wire brush and/or
vacuum clean the combustion chamber as needed to remove scale deposits and
debris. NOTE: It is imperative for proper operation of the water heater that the
inner door be replaced in the original location, making certain the resetable
thermal switch is properly connected to the gas control wire leads provided.
WARNING
IMPORTANT
The water heater should be inspected at a minimum annually by a qualified
service technician for damaged components and/or joints not sealed. DO NOT
operate this water heater if any part is found damaged or if any joint is found
not sealed.
- 50T-65FB-3X U-65T-55FR-3N U-50T-55FR-3N 65T-65FB-3N 50T-65FB-3N PE-2-XR504T6FSX PE-4-5036FSX PE-4-40T6FSX PE-4-403S6FSX HE-4-50S6FSX HE-4-40S6FSX M-2-XR65T6FSX M-2-XR504T6FSX M-1-XR403S6FSX M-4-60T6FSX M-4-5036FSX M-4-403S6FSX M-4-40T6FSX M-4-30T6FSX M-I-60T6FSX M-I-504S6FSX M-I-50L6FSX M-I-5036FSX M-I-404T6FSX M-I-403S6FSX M-I-40T6FSX M-I-30S6FSX M-I-303T6FSX M-I-30T6FSX U2-XR-65T6FRN U2-XR-75S6RN U2-XR-504T6FRNU2-XR-504T6FRN U1-XR-403S6FRN U4-60T6FRN U4-5036FRN U4-40T6FRN U4-403S6FRN U4-30T6FRN U1-60T6FRN U1-5036FRN U1-403S6FRN U1-504S6FRN U1-404T6FRN U1-30T6FRN U1-50L6FRN U1-40T6FRN U1-30S6FRN PE-2-XR504T6FBN PE-4-5036FBN PE-4-40T6FBN PE-4-403S6FBN HE-4-50S6FBN HE-4-40S6FBN M-2-XR65T6FBN M-2-XR504T6FBN M-1-XR403S6FBN M-4-60T6FBN M-4-5036FBN M-4-403S6FBN M-4-40T6FBN M-4-30T6FBN M-I-60T6FBN M-I-504S6FBN M-I-50L6FBN M-I-5036FBN