238‐49754‐00B  2/12 

 

For the exhaust venting for all power vent and power direct  

For Commercial Power Direct Vent models, insert  

vent models, insert the PVC Adapter into the Exhaust Outlet  

PVC Adapter into Exhaust Outlet Adapter. 

Adapter.  On residential models, tighten the clamp to secure  

Install Flue Clamp over Exhaust Outlet Adapter and 

the PVC Adapter. 

 

 

 

 

 

Tighten clamp screw to secure the PVC Adapter. 

 

 

 
 
 
 
 
Step 4:  Lubricate the inside gasket of the PVC adapter and the male end (without gasket) of the elbow or straight 
section of pipe for running the exhaust or intake pipe from the water heater.  Insert the male end of the elbow or 
straight section into the PVC adapter.  Use a twisting motion while pushing the male end of the pipe or elbow into the 
PVC adapter to fully seat into the gasket.  The male end of the pipe or elbow must always point toward the water 
heater. 
 
Apply Centrocerin lubricant to the inside gasket of the PVC adapter. 
 

 

Exhaust Outlet Adapter with clamp for residential 
power vented models.   

Inside Gasket of Centrotherm PVC Adapter 

Apply Centrocerin Lubricant to Gasket with 
finger 

Commercial Power Direct Vent Exhaust 
Outlet Adapter 

Flue Clamp – Tighten Screw 

PVC Adapter