14. Drum stop time

If the machine is equipped with a reversing drum motor, and program parameter 13 is set to
reversing, this parameter allows the time the drum will stop when switching direction to be
defined. So, after running for the time defined in parameter 16, the drum will stop for the
time defined in parameter 15 and then start again in the other direction. If no reversible drum
is installed or the drum direction is not set to reverse, this parameter will not be available.

Note:

This value is an additional value to the minimum stop time, which is 4 seconds. So, for
example, if this parameter is set to a value of 6, the stop time will be 6 + 4 = 10 seconds.

15. Drum run time

If the machine is equipped with a reversing drum, and program parameter 13 is set to re-
versing, this parameter is the time the drum runs in one direction. After running for the time
defined in parameter 16, the drum will stop for the time defined in parameter 15 and then
start again in the other direction. If no reversing drum is installed or the drum direction is
not set to reverse, this parameter will not be available.

16. Anti crease funct.

This parameter indicates if the anti-crease function is enabled in this program. When a pro-
gram finishes, the drum will stop for 2 minutes. If anti-crease is enabled the drum will run
again for two minutes, then pause for 2 minutes. This will continue until the door is opened.
During anti-crease the blower will not be on. This means that if the drum motor is connected
together with the blower motor, the anti-crease function will not work.

17. Max. temp rise

The maximum temperature rise rate in degrees per minute during a drying cycle. During
drying the controller will adjust the temperature control function so that the temperature
will not rise more than this programmed maximum. If this value is set to 0, no maximum
rise is active, and the controller will try to reach goal temperature is soon as possible.

18. Max. temp fall

The maximum temperature fall rate in degrees per minute during a cool-down cycle. During
cool-down the controller will adjust the temperature control function so that the temperature
will not fall more than this programmed maximum. If this value is set to 0, no maximum fall
is active, and the controller will try to reach goal temperature is soon as possible

4.5.2

Edit Program Name

A program name can be set for each program. This name describes the type of material for which
the program has been set up. The maximum length of a program name is 32 characters.

When the screen is activated, the cursor will be on the first character. The cursor can be moved
with the A

RROW

U

P

and A

RROW

D

OWN

keys.

25