Installation, Mounting bolt installation, Machine foundation – B&C Technologies HI Series Commercial User Manual
Page 18: Floor detail

18
Installation
HI-125
HI-85
Mounting Bolt Installation
The HI Series uses 5/8-11 x 8” bolts.
Embed the bolts in 3500 psi reinforced
concrete with a minimum of 12” thickness.
The threaded end of the bolt should extend
2 inches from the surface of the floor. As an
option, a welded bolt locating fixture is
available (rebar frame). This rigid welded
assembly is made of reinforcing rod (rebar)
and is designed to be encased in concrete.
Machine Foundation
Dynam ic Frequency
kN
lbs
kN/m 2
lbs-ft2
kN
lbs
kN/m 2
lbs-ft2
HI-85
7.56
1700
5.01
104.64
17.39
3910
11.52
240.6
HI-125
19.53
4390
10.64
222.22
25.58
5750
13.93
290.93
Hz
9.65
8
S tatic floor load
S tatic pressure
Dynam ic floor load Dynam ic pressure
6
.1
1
5
5
6
.1
1
5
5
1
5
.7
5
4
0
0
1
5
.7
5
4
0
0
4
101
4
101
15.2
386
3X
1
25
61.4
1560
5
1
.6
1
3
1
0
[email protected] (17)
Floor Detail