Failover support configuration details, Failover reference configuration 1, Lt04 configurations lt05 configurations – Dell PowerVault TL4000 User Manual
Page 4: Configuration samples
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Dell PowerVault^*^ TL4000/TL2000 Failover Guide
LT04 Configurations
LT05 Configurations
•
Two homogeneous (Fibre Channel or SAS)
•
Two or more homogeneous
(Fibre
LT04 full height drives in a single library
Channel or SAS) LT05 drives in a
single
partition
library partition
•
Control path enabled on all drives in the
•
Control path enabled on all drives
in the
partition
partition
•
Microsoft yyindows 2003, Windows 2008
•
Microsoft Windows 2003, Windows 2008,
or Windows 2008 R2 installed in the host
or Windows 2008 R2 installed on the host
server
server
•
Dell PowerVault™ TL4000 library device
•
Dell PowerVault™ TL4000\TL2000 library
driver running on host server
device driver running on host server
•
CommVault Galaxy 6.1 SP4 or later or
•
CommVault Galaxy 7.0 SP4 or
later
Commvault Simpana 7.0 SP4 or later
installed in the host system
installed in the host system
•
Failover activated via license key on the
•
Failover activated via license key on the
Dell PowerVault™ TL4000 or TL2000
Dell PowerVault™ TL4000 library
library
•
Shared Storage license applied to the
•
Shared Storage license applied to the
CommVault backup application
CommVault backup application
Table 3: Failover Configuration Requirements
Failover Support Configuration Details
This section details the configuration requirements that must be meet in order to support failover using
the Dell PowerVault™ TL2000 or TL4000 library.
Important Note: Failover support is limited to the Dell PowerVault™ TL4000 when configured with LT04
drives.
Configuration Samples
Please refer to the following diagrams for cabling the supported failover configurations. The drive
shown as the failover path does not need to be on standby (i.e. not in use) for failover to occur.
Failover Reference Configuration 1:
One host, one Fibre Channel switch and one Dell PowerVault^*^ library with two Fibre Channel
drives
In this configuration, failover occurs if one of the drives in the library fails (hardware failure or drive is
disconnected from the Fibre Channel switch). The physical connection of this configuration is shown in
Figure 1.
Important Note: The Fibre Channel Drive Generation can be LT04 or LT05
4 j P a g e
1 2 / 3 1 / 0 9 v e r s i o n 2 . 0
Always refer to www.de!l.comXsuPDort for latest documentation and updates