beautypg.com

Split system operations chart, Ss050, Ss088 – Wine Guardian Ducted Split Wine Cellar Cooling Systems (SS200) User Manual

Page 44: Ss200

background image

39

Split System Operations Chart

OD Ambient (F)

Suction (psig)

Discharge (psig) Superheat (F) Sub-cooling (F)

10

21

86

3

15

40

25

102

9

16

60

31

105

8

24

70

31

106

12

24

80

32

120

16

21

100

34

164

24

27

115

35

198

28

35

SS050

OD Ambient (F)

Suction (psig)

Discharge (psig) Superheat (F) Sub-cooling (F)

10

24

86

5

20

40

26

102

5

16

60

28

109

5

17

70

27

114

11

22

80

27

134

13

25

100

27

179

22

30

115

28

215

27

33

SS088

OD Ambient (F)

Suction (psig)

Discharge (psig) Superheat (F) Sub-cooling (F)

15

22

98

5

15

40

23

95

5

17

60

25

108

8

20

70

27

130

10

22

80

28

146

17

24

100

30

193

20

28

115

33

230

23

30

SS200

OD Ambient (F)

Suction (psig)

Discharge (psig) Superheat (F) Sub-cooling (F)

15

*25 (avg.)

*107 (avg.)

*5 (avg.)

*11 (avg.)

40

*27 (avg.)

*112 (avg.)

*5 (avg.)

*11 (avg.)

60

28

106

8

5

70

28

123

15

10

80

29

123

13

10

100

30

141

14

10

115

31

210

25

15

Table 4