Operators guide
39
Troubleshooting
Fault
Check
Read
Power supplied but the
camera cradle is not
moving.
Check that the tilt lock is
disengaged.
Locking the camera
cradle on page 30
Head not operating.
Check that the power switch is ON.
Powering up on
page 30
Ensure that the power and
Ethernet cables are connected and
secure.
Power and Ethernet
connections on
page 20
Check the power supply to the
head. Check that power is being
supplied from the pedestal or
height drive or studio supply.
If operating the head remotely,
check that the camera is enabled
on the control panel. The Camera
button appears white when the
camera is online and is greyed out
when the camera is offline and the
head set to manual operation.
Switching the FH-100
head to robotic mode
on page 31
Check the head fuses and replace
as necessary. The head requires
two T6.3A fuses.
Changing a fuse on
page 38
Camera and payload
moving too far on the
pan and tilt axis in
robotic operation.
Check and if necessary reset the
pan and tilt limits using the Fusion
Setup and Test configuration
software tool.
Setting pan and tilt
movement limits on
page 27
Camera operator unable
to move the head about
the pan and tilt axis.
Check that the pan and tilt axis are
switched to manual operation. The
pan and tilt robotic/manual rotary
switches must be set to MAN.
Switching the FH-100
head to manual mode
on page 33
Camera and payload
falling away when the
camera cradle is tilted.
The head and payload require
balancing.
Balancing the head
and payload on
page 25