Tjernlund SS2G SideShot (Discontinued) 8504075 Rev 1 11/98 User Manual
Page 2

1
Tjernlund Products welcomes your comments and questions.
Address all correspondence to:
Customer Service
Tjernlund Products, Inc.
1601 Ninth Street
White Bear Lake, MN 55110-6794
or contact Tjernlund Products at 800-255-4208.
TABLE OF CONTENTS
Page (s)
Description and Specifications ....................................................................................................................................1, 2
Installation Restrictions .................................................................................................................................................2
Cautions .....................................................................................................................................................................2, 3
Safety Inspection of a Previously Used Gas Appliance ..................................................................................................3
SideShot
®
Model SS2G Terminology .............................................................................................................................3
Vent Hood Termination Clearances, Clearances to Combustibles & Obstructions ....................................................... 4
Installation
Tools Required .................................................................................................................................................5
Vent System Installation ..........................................................................................................................5, 6, 7
Installation of Vent Pipe ....................................................................................................................................7
Electrical Wiring
Wiring Restrictions ........................................................................................................................................7, 8
SS2G Wiring with Single Zone Thermostat.......................................................................................................8
Wiring to 24V Gas Valve ...............................................................................................................................8, 9
Draft Adjustment Procedure............................................................................................................................10
Combustion Air ............................................................................................................................................................. 10
Final System Operation Check Out ..............................................................................................................................10
Troubleshooting Electrical Problems .......................................................................................................................11, 12
Maintenance ..................................................................................................................................................................13
How to Obtain Service...................................................................................................................................................13
Warranty & Replacement Parts .....................................................................................................................................13
SS2G Vent Cabinet Mounting Template .......................................................................................................................14
SideShot
®
is a registered trademark of Tjernlund Products, Inc. for their Model SS2G Vent System.
DESCRIPTION
The SS2G is a mechanical vent system designed and listed for use with natural draft gas heating equipment. It is factory assem-
bled and wired. The SS2G automatically vents the flue gases from heating equipment to the outdoors. By recirculating indoor air
with a cooling fan, surrounding combustible materials remain at safe temperatures. After each burner cycle the SS2G will continue
to operate for a nonadjustable timed period of approximately 45 seconds to purge the heater and vent of residual flue gases. The
SS2G features a safety system consisting of a Fan Proving Switch and a High Limit temperature control. These devices monitor
the SS2G’s performance and will interrupt the main burner if a venting malfunction is detected.
APPLICATION TABLE
Verify that the total BTU/hr. input of the heating appliance(s) falls within the inputs listed below. The BTU/hr. capacity range is
based on a maximum of 50 equivalent feet. To determine equivalent feet, add the total length of straight vent pipe plus 10 feet for
each 90 degree elbow and 5 feet for each 45 degree elbow. Vent runs of over 15 linear feet require the use of an approved, insu-
lated vent connector to prevent problems related to condensation.
MODEL
Atmospheric
Natural & LP Gas
Fan Assisted
Natural & LP Gas
Max. Equivalent
Feet
SS2G
40,000-125,000 BTU/hr
40,000-150,000 BTU/hr
50