In Canada:

a. Current CGA B149.1 and CGA B149.2 installation code for Propane

Appliances and Equipment.

b. Current CSA Z240.4.2 Installation Requirement for Propane Appliances

and Equipment in Recreational Vehicles.

c. Current CSA Z240.6.2/C22.2 No. 148 Electrical Requirement for

Recreational Vehicles.

When installed, the refrigerator must be electrically grounded in accordance with Canadian Electrical Code C22.2

Parts 1 and 2.

Preparing for Installation

Refrigerator Ventilation Requirements

Venting is required in an R.V. refrigerator application to remove products of combustion, to isolate the living space

of the vehicle from the refrigerator’s combustion system, to remove excess heat from refrigerator’s cooling system
generator area, and to remove heat that is extracted from the refrigerator cabinet.

Certified installation requires that one intake vent and one exhaust vent be used. Refer to Table 1 on page 4. To

insure adequate refrigerator performance, a continuous air flow is required across the refrigerator’s cooling system.

The intake vent also serves as a service access door. The bottom of the intake vent opening must be flush with

or below the surface on which the refrigerator is mounted. This configuration allows any leaking propane to ventilate
to the outside of the coach.

The refrigerator is certified for
built-in installation. Follow en-
closure requirements for in-
stallation certification.

In

stal

latio

n

Requ

iremen

ts

Figure 1

Certified Refrigerator
Enclosure Requirements

Solid level floor

Do not place refrigerator directly on
carpet.

Place refrigerator on metal or wood
panel extending at least full width and
depth of refrigerator.

Floor must support refrigerator and
it’s food load

No adjacent heat sources

No combustible materials stored
near the refrigerator

Enclosure Cut-Out Dimensions:

982/983

9182/9183

962/963

9162/9163

Height (A)

59 7/8"

52 7/8"

Width (B)

23 1/2"

23 1/2"

Depth (C)

24"

24"

WARNING

Hazardous gas! Carbon monoxide can cause nausea, fainting, or death. Inadequate

ventilation or partial blockage of refrigerator’s flue can result in increased carbon monoxide emissions
when operating in the gas mode. To prevent emission of hazardous levels of carbon monoxide, installation
must assure complete isolation of the living space of mobile home or R.V. from refrigerator’s combustion
system. Follow Norcold’s Ventilation and Installation recommendations explicitly.