beautypg.com

Smart Power Systems HR-12 50 Hz User Manual

Page 13

background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 12 of 54


4.

Verify that the drive shaft selected will couple to both the PTO and the SPS
supplied pump. Pumps supplied by Smart Power

®

Systems for this system have an

SAE C, 1.25” keyed shaft.


WARNING:


The installer must provide guarding to prevent damage to the pump seals from road
debris. Also, properly sized and installed vibration isolators must be used if the
pump is mounted to the chassis. Failure to do either will void the system’s
warranty.

Never use an unbalanced drive shaft to drive a remotely located pump. An
unbalanced drive shaft will cause premature wear of the pump and will void the
system’s warranty.

Do not approach a running A.C. modular generator when wearing long, loose items
such as hair, jewelry, ties, clothing, etc. Direct contact with a rotating drive shaft
can cause serious personal injury and/or damage to the system.


5.

Obtain the following hoses of the necessary length for the installation:


a) Pump inlet hose: 1” SAE 100R1AT-16 hose with Parker hose ends P/N 10643-

16-16. Note: Maximum hose length is 20’.

b) Pump outlet hose: 1/2” SAE 100R9AT-8 rated to 4000 PSI (use Parker hose

ends, part number 10643-8-8). Note: Maximum hose length is 20’.

c) Pump case drain hose: 5/8” SAE 100R1AT-10 (use Parker hose ends, part

number 10643-10-10). Note: Maximum hose length is 20’.


This manual is related to the following products: