Caution hot water, Caution hot steam – Sage Oracle BES980UK User Manual
Page 18

35
36
PAge heAder.....
PAge heAder.....
Step 4 – Empty de-scale Solution
The GRIND LCD will display 04 during
Step 4 procedure.
a)
Empty water tank, rinse and fill water
tank with clean water. Insert water tank
into machine.
b)
Rotate left screw first, counter-clockwise
until fully open. Water will begin to flow
into drip tray.
c)
Repeat with right screw. Steam will be
released from the boiler.
CAUTION HOT WATER
d)
Close valves when water stops flowing
through both outlets. Empty drip tray
and re-assemble onto unit.
CAUTION HOT STEAM
Step 5 – fill Boilers
The GRIND LCD will display 05 during
Step 5 procedure.
5 minute timer will begin. Wait for
countdown timer to get to 0:00.
(This allows any remaining solution
to be removed from system).
CArE & CLEAnIng
CArE & CLEAnIng
Step 6 – flush Boilers
The GRIND LCD will display 06 during
Step 6 procedure.
a)
Empty water tank, rinse and assemble
new water filter into tank.
b)
Fill water tank with clean water and
insert into machine.
c)
Rotate screws counter-clockwise, as per
previous instructions until fully open.
Water will begin to flow into drip tray.
d)
Close valves when water stops flowing
through both outlets. Empty drip tray
and re-assemble onto unit.
CAUTION HOT WATER
e)
Empty drip tray and re-insert
into machine.
f)
Push SELECT button to complete the
de-scale procedure. Machine will heat
up as normal.
SELECT
SELECT
SELECT
TEMP TEXTURE
TEMP TEXTURE