Cell voltage monitor celllog 8m, Quick start – ProgressiveRC 8M CellLog User Manual
Page 8

-8-
Cell Voltage Monitor CellLog 8M
TYPE
XXXXXXXXXX
Do not support
the logging!
QUICK START
CellLog Power On
(2 ways: one is connecting the battery through the left 9 Pin socket, the other one is through the USB port),
System self-check, and then shows the SN and version number, the display information are as below:
The first line is the current selected Setting Type (See
detail in P10).
Note: CellLog 8M has no Logging function, if it is necessary,
please choose CellLog 8S.
Voltage Monitor
There are 4 interface choices, which can be shifted by <▲> or <▼>buttons.
As the left pictures: the ‘7‘ in ‖7S‖ means cell counts; ‘6H‘
means the 6
th
cell voltage is the highest; ‘1L‘ means the 1
st
cell voltage is the lowest.
If the monitor voltage trigger alarm, the corresponding
voltage and alarm display (LOW, OVER or DIFF) shows
alternatively.
The cell number and (L, O, D) shows alternatively.
‘LOW‘ or ‗L‘ means: Low voltage alarm
‘OVER‘ or ‗O‘ means: Over voltage alarm
‘DIFF‘ or ‗D‘ means: Voltage difference alarm. They will be
displayed at the same time at the highest and the lowest
cell voltage interface.
Monitor the pack voltage
Display respectively: Current pack voltage, Max. Pack
voltage, Min. Pack voltage, Pack voltage difference. (▣P =
HV-LV
)
Data Holding
When in Voltage Monitor status, press <▼> button for 3 seconds, after it shows ‖Start holding…‖, the
calculagraph will be shown alternatively at the upper right corner of the LCD screen.
Press <▼> for 3 seconds again, the screen will show ‖Stop holding!‖ and then exit.
View holding Point
In the monitor status, press <▲> and <▼> at the same time to enter the view logging point status.
Three points voltage data can be searched:‖Starting holding…‖data, ‖Stop holding!‖ data, and the data of
voltage alarm during this period , which can be shifted by < > buttons. Press < > for 3 seconds,it will return
to the monitor status.
The saved data can be covered till next logging.
If the logging time is over the users setting safety time,(See Monitor Safety Time Setting in P11), it will
trigger Safety Time Alarm, and the screen shows ‖T_OVER‖ alternatively in the upper right corner.
Alarm configuration Name
Notes
1234567-
7S
28.79
6H
4.162
1L
4.013
▣
V
149mV
Pack Voltage
The highest voltage
The lowest voltage
The maximum
voltage difference
Cell Number
Voltage
Histogram
1
4.013V
2
4.150V
3
4.110V
4
4.152V
5
4.087V
6
4.162V
7
4.120V
8
------
Cell Voltage
Cell Number
7S
28.79V
▣
V
149mV
1
4.01
2
4.15
3
4.11
4
4.15
5
4.08
6
4.16
7
4.12
8
----
Pack Voltage
The Max. Voltage
difference
Cell Number
Cell Voltage
7S
28.79V
HV
28.80V
LV
28.78V
▣
P
0.020V
Pack Voltage
Max. Pack Voltage
Min. Pack Voltage
Pack Voltage Difference
<▢>
<▼>
<▢>
<▼>
<▢>
<▼>