ProgressiveRC 8M CellLog User Manual
Page 12

-12-
Cell Voltage Monitor CellLog 8M
SAVE TIME SET
Minutes(1-240)
005
SYSTEM SETTING
Beep Tone
LCD Screen
ALM Output
BEEP TONE
Key Tone
Hint Tone
Alarm Tone
Brightness
-
■■■■■■
+
Contrast
-
■■■■■■
+
ALARM OUTPUT
⊙NO.
○NC.
START SETTING
Start Music
Logo Screen
Inf.Screen
Save Time Set
Parameter Setup
Press < > for 3 seconds, and enter to the MAIN MENU, Monitor status.
System Settings: Select【System…】, press < >, the screen shows:
<▲> or <▼> to select items, press < > to have a select item, press
< > for more than 3 seconds to return.
See details below.
1) Beep Tone Settings: Select【Beep Tone】, press < >, the screen shows:
<▲> or <▼> to select the items, and press < > to shift select /,
press < > for 3 seconds to confirm the amendment and then return.
Select【Key Tone】,the buttons tone open.
Select【Hint Tone】,the status tone open.
Select【Alarm Tone】,the alarm tone open. (―Do‖ every 4 seconds)
2) LCD Brightness & Contrast Setting : Select【LCD Screen】, press < >, the screen shows:
<▲> increase, <▼> decrease, and press < > to shift
Brightness/Contrast, press < > for 3 seconds to confirm the
amendment and then return.
3) Alarm Output Signal Type Setting:【ALARM Output】
【
NO.】: Always On. Two output of ALM, it‘s open when there is no
alarm; It‘ short circuit with alarm.
【
NC.】: Always Close. Two output of ALM, it‘s short circuit when there
is no alarm; It‘s open with alarm.
4) Start-up Setting:【Start…】
<▲> or <▼> to select the items, and press < > to shift select /,
press < > for 3 seconds to confirm the amendment and then return.
Select【Start Music】, there will be a start music if you turn on
Select【Logo Screen】, it will display Logo Screen if you turn on
Select【Inf. Screen】, it will display Information Screen if you turn on
5) Power management Setting:【Power management】
The item with is the current setting.
【
Not Save】, power save function turns off
【
Backlight OFF】, turns off LCD backlight
【
Sleep Mode】, turns off LCD backlight & MCU enters to Sleep Mode
Press < > to【Save Time Set】
No operation in setting time, the system will enter to the selected
Power Save Mode automatically. Press any key to normal Mode.
MAIN MENU
System...
Calibration
POWER MANAGEMEN
⊙Not Save
○Backlight OFF
○Sleep Mode
< >